X-RAY-EMISSION FROM BROADCAST TRANSMITTERS

被引:0
作者
HUNTER, EB
机构
[1] Greenville, North Carolina 27834, Route 1
关键词
D O I
10.1109/11.52360
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
During the past few years, amplitude-modulated transmitters employing efficient pulse-width modulators have come into common use. These transmitters are reliable, relatively insensitive to vacuum tube characteristics, and offer excellent audio fidelity; however, their architecture requires supply voltages in the 20 to 30 kilovolt range which greatly enhances th e production of ionizing radiation in the form of x-rays. Recent analysis by Voice of America indicates that these x-rays are being emitted in short, high-intensity bursts focused into broad radial beams. Part I of this paper reviews the general aspects of ionizing radiation of interest to communications engineers. Part II examines the spectral and time domain characteristics of x-ray radiation from transmitters, suggests a method for estimating fault condition radiation values, and discusses the findings of the Voice of America. © 1990 IEEE
引用
收藏
页码:14 / 23
页数:10
相关论文
共 8 条
[1]  
Anderson D. W., 1984, ABSORPTION IONIZING
[2]  
DYSON NA, 1973, XRAYS ATOMIC NUCLEAR
[3]  
HENDEE WR, 1979, MED RAD PHYSICS
[4]  
KHAN FM, 1984, PHYSICS RAD THERAPY
[5]  
Tsoulfanidis N., 1983, MEASUREMENT DETECTIO
[6]  
ICRU17 INT COMM RAD
[7]  
1986, HLTH PHYSICS RADIO S, V1
[8]  
[No title captured]