TONOMETRY IN THE GENERAL-PRACTICE SETTING .1. TONO-PEN COMPARED TO GOLDMANN APPLANATION TONOMETRY

被引:0
|
作者
CHRISTOFFERSEN, T
FORS, T
RINGBERG, U
HOLTEDAHL, K
机构
[1] UNIV TROMSO, DEPT OPHTHALMOL, N-9001 TROMSO, NORWAY
[2] UNIV TROMSO, NORDBYEN MED PRACTICE, N-9001 TROMSO, NORWAY
[3] UNIV TROMSO, INST COMMUNITY MED, N-9001 TROMSO, NORWAY
关键词
AGREEMENT BETWEEN METHODS; APPLANATION TONOMETRY; GENERAL PRACTICE; INTEROBSERVER AGREEMENT; TONOMETRY; TONO-PEN;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraocular pressure was measured in 132 consecutive patients over the age of 20 in a general pratice with two general practitioners (GP). Tono-Pen tonometry was compared to Goldmann applanation tonometry in a masked, randomized design. Also, agreement between Tono-Pen measurements by the GPs and the ophthalmologist was estimated. Both mean difference between Tono-Pen and Goldmann applanation measurements and mean differences between Tono-Pen readings made by GPs and ophthalmologist were less than 1 mmHg. Ninety-five percent limits of agreement between the two methods were approximately -4.5 mmHg and 5.5 mmHg, and between observers approximately -4 mmHg and 5 mmHg. The Tono-Pen was agreeable both to patients and physicians. The GPs made as accurate measurements as the ophthalmologist. The wide limits of agreement are clinically much more important than the small differences between means. Random variation was much greater than systematic variation. Wide limits of agreement will apply to all known methods of clinical tonometry.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [31] THE EFFECT OF PERKINS, TONO-PEN, AND SCHIOTZ TONOMETRY ON INTRAOCULAR-PRESSURE
    WHITACRE, MM
    EMIG, M
    HASSANEIN, K
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (01) : 59 - 64
  • [32] Evaluation of TGDc-01 compared with Goldmann applanation tonometry
    Rombold, F
    Thiel, MJ
    Neubauer, AS
    Hirneiss, C
    Kampik, A
    OPHTHALMOLOGE, 2005, 102 (02): : 158 - 162
  • [33] Comparison of Goldmann Applanation, Noncontact Air Puff, and Tono-Pen XL Tonometry in Normal Controls versus Glaucoma Patients at a University Hospital in Riyadh, Saudi Arabia
    Osman, Essam A.
    Gikandi, Priscilla W.
    Al-Jasser, Abdul-Rahman A.
    Alotaibi, Majeedah
    Mousa, Ahmed
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2018, 25 (01) : 8 - 13
  • [34] Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry
    Niles, Charles R.
    Crinzi, Alexander R.
    Bonaventura, Russell
    Taylor, David A.
    FRONTIERS IN OPHTHALMOLOGY, 2024, 4
  • [35] Comparison of the Utility of Pascal Dynamic Contour Tonometry With Goldmann Applanation Tonometry in Routine Clinical Practice
    Anderson, Matthew Frederick
    Agius-Fernandez, Adriana
    Kaye, Stephen B.
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 422 - 426
  • [36] Measurements of Intraocular Pressure with Tono-Pen and Goldmann Applanation Tonometers in Subjects with Systemic Illness
    Hsu, Sheng-Yao
    Lin, Shu-Fang
    Hsu, Ai-Hsi
    TZU CHI MEDICAL JOURNAL, 2007, 19 (04): : 241 - 244
  • [37] Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma
    Carrim, Zia I.
    Lavy, Tim E.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (06) : 648 - 651
  • [38] Comparison of Tono-Pen and Goldmann applanation tonometers for measurement of intraocular pressure in healthy children
    Bradfield, Yasmin S.
    Kaminski, Brett M.
    Repka, Michael X.
    Melia, Michele
    JOURNAL OF AAPOS, 2012, 16 (03): : 242 - 248
  • [39] Clinical comparison of the Proview™ eye pressure monitor with Goldmann applanation tonometer and Tono-Pen
    Li, J
    Herndon, LW
    Stinnett, S
    Asrani, SG
    Allingham, RR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U13 - U13
  • [40] TONO-PEN, A NEW HAND-HELD TONOMETER - COMPARISON WITH THE GOLDMANN APPLANATION TONOMETER
    HESSEMER, V
    ROSSLER, R
    JACOBI, KW
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 193 (04) : 420 - 426