TONOMETRY IN THE GENERAL-PRACTICE SETTING .1. TONO-PEN COMPARED TO GOLDMANN APPLANATION TONOMETRY

被引:0
|
作者
CHRISTOFFERSEN, T
FORS, T
RINGBERG, U
HOLTEDAHL, K
机构
[1] UNIV TROMSO, DEPT OPHTHALMOL, N-9001 TROMSO, NORWAY
[2] UNIV TROMSO, NORDBYEN MED PRACTICE, N-9001 TROMSO, NORWAY
[3] UNIV TROMSO, INST COMMUNITY MED, N-9001 TROMSO, NORWAY
关键词
AGREEMENT BETWEEN METHODS; APPLANATION TONOMETRY; GENERAL PRACTICE; INTEROBSERVER AGREEMENT; TONOMETRY; TONO-PEN;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraocular pressure was measured in 132 consecutive patients over the age of 20 in a general pratice with two general practitioners (GP). Tono-Pen tonometry was compared to Goldmann applanation tonometry in a masked, randomized design. Also, agreement between Tono-Pen measurements by the GPs and the ophthalmologist was estimated. Both mean difference between Tono-Pen and Goldmann applanation measurements and mean differences between Tono-Pen readings made by GPs and ophthalmologist were less than 1 mmHg. Ninety-five percent limits of agreement between the two methods were approximately -4.5 mmHg and 5.5 mmHg, and between observers approximately -4 mmHg and 5 mmHg. The Tono-Pen was agreeable both to patients and physicians. The GPs made as accurate measurements as the ophthalmologist. The wide limits of agreement are clinically much more important than the small differences between means. Random variation was much greater than systematic variation. Wide limits of agreement will apply to all known methods of clinical tonometry.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [1] Tono-Pen versus Goldmann Applanation Tonometry
    Bao, Bo
    Diaconita, Vlad
    Schulz, David C.
    Hutnik, Cindy
    OPHTHALMOLOGY GLAUCOMA, 2019, 2 (06): : 435 - 439
  • [2] Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry
    Hsu, S-Y
    Sheu, M-M
    Hsu, A-H
    Wu, K-Y
    Yeh, J-I
    Tien, J-N
    Tsai, R-K
    EYE, 2009, 23 (07) : 1582 - 1588
  • [3] Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry
    S-Y Hsu
    M-M Sheu
    A-H Hsu
    K-Y Wu
    J-I Yeh
    J-N Tien
    R-K Tsai
    Eye, 2009, 23 : 1582 - 1588
  • [4] Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas
    Kontadakis, George A.
    Pennos, Alexandros
    Pentari, Iro
    Kymionis, George D.
    Pallikaris, Ioannis G.
    Ginis, Harilaos
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2020, 12
  • [5] TONOMETRY COMPARISON - GOLDMANN VERSUS TONO-PEN
    KOONER, KS
    COOKSEY, JC
    BARRON, JB
    ZIMMERMAN, TJ
    GUPTE, RK
    WALL, JL
    ANNALS OF OPHTHALMOLOGY, 1992, 24 (01): : 29 - 36
  • [6] Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
    Badakere, Swathi Vallabh
    Choudhari, Nikhil S.
    Rao, Harsha L.
    Chary, C. Raghava
    Garudadri, Chandra Sekhar
    Senthil, Sirisha
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) : 129 - 135
  • [7] TONO-PEN TONOMETRY
    BEAUMONT, P
    KANG, K
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (11) : 754 - 754
  • [8] Effect of Corneal Stiffening on Goldmann Applanation Tonometry and Tono-Pen Measurements in Canine Eyes
    Tang, Junhua
    Pan, Xueliang
    Weber, Paul A.
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (03) : 1397 - 1405
  • [9] Corneal Modulus and IOP Measurements in Canine Eyes Using Goldmann Applanation Tonometry and Tono-pen
    Tang, Junhua
    Pan, Xueliang
    Weber, Paul A.
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 7866 - 7871
  • [10] OCULAB TONO-PEN, GOLDMANN APPLANATION TONOMETRY, AND PNEUMATIC TONOMETRY FOR INTRAOCULAR-PRESSURE ASSESSMENT IN GAS-FILLED EYES
    HINES, MW
    JOST, BF
    FOGELMAN, KL
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 106 (02) : 174 - 179