Reverse Total Shoulder Arthroplasty-Biomechanics and Rationale

被引:11
作者
Hsu, Stephanie H.
Greiwe, Raymond M.
Saifi, Comron
Ahmad, Christopher S.
机构
[1] Columbia Univ, Med Ctr, Dept Orthopaed, New York, NY USA
[2] Columbia Univ, New York Presbyterian Hosp, Med Ctr, Ctr Shoulder Elbow & Sports Med,Dept Orthopaed Su, New York, NY USA
关键词
biomechanics; cuff tear arthropathy; reverse total shoulder arthroplasty;
D O I
10.1053/j.oto.2010.10.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reverse total shoulder arthroplasty (RTSA) was designed to provide pain relief, improve functional results, and reduce the risk of implant failure in patients with a painful rotator cuff-deficient shoulder. Understanding the biomechanics and rationale behind the surgical technique and its relationship to implant design is essential. The design and biomechanics of RTSA is based upon principles put forth by Grammont. These are inherent prosthetic stability, convexity of the glenoid components with complementing concavity of the humeral component, glenosphere center placement at or within the glenoid neck, and a medialized and distalized center of rotation. In addition, patient selection, surgical technique, and postoperative management all factor in the functional success of RTSA. Component sizing, version, glenoid baseplate fixation and placement, humeral neck-shaft angle and distalization, and surgical approach are all choices made by the informed surgeon. Each factor plays a role in the functional outcome of an RTSA and its potential complications. (c) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 45 条
[1]   Moment Arms of the Shoulder Musculature After Reverse Total Shoulder Arthroplasty [J].
Ackland, David C. ;
Roshan-Zamir, Sasha ;
Richardson, Martin ;
Pandy, Marcus G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1221-1230
[2]   Grammont reverse prosthesis: Design, rationale, and biomechanics [J].
Boileau, P ;
Watkinson, DJ ;
Hatzidakis, AM ;
Balg, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :147S-161S
[3]   Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplasty [J].
Boileau, Pascal ;
Watkinson, Duncan ;
Hatzidakis, Armodios M. ;
Hovorka, Istvan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) :527-540
[4]   Reverse total shoulder arthroplasty after failed rotator cuff surgery [J].
Boileau, Pascal ;
Gonzalez, Jean-Francois ;
Chuinard, Christopher ;
Bicknell, Ryan ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) :600-606
[5]  
Boulahia A, 2002, ORTHOPEDICS, V25, P129
[6]  
BROSTROM LA, 1992, CLIN ORTHOP RELAT R, P155
[7]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[8]   Arthroscopic rotator cuff repair [J].
Burkhart, SS ;
Lo, IKY .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (06) :333-346
[9]  
BURKHART SS, 1991, CLIN ORTHOP RELAT R, P45
[10]  
Byaley I, 1982, KESSEL TOTAL SHOULDE