MANAGEMENT OF DIFFICULT CORONARY SINUS RUPTURE

被引:12
作者
WEISS, SJ
机构
[1] Albert Einstein Medical Center, Philadelphia, PA
关键词
D O I
10.1016/0003-4975(94)92252-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A technique of handling severe coronary sinus rupture when direct suture repair or pericardial patch techniques have failed is described. A pericardial patch is sewn over the coronary sinus with running 5-0 Prolene suture, and an 8-mm thin-walled Gore-Tex conduit then is constructed between the patch and the right atrium to decompress the repair and allow an alternative route for coronary sinus return to the right atrium.
引用
收藏
页码:548 / 550