2-COLOR MULTIPARAMETRIC METHOD FOR FLOW CYTOMETRIC DNA ANALYSIS

被引:8
|
作者
BROWN, RD [1 ]
ZARBO, RJ [1 ]
LINDEN, MD [1 ]
TORRES, FX [1 ]
NAKHLEH, RE [1 ]
SCHULTZ, D [1 ]
MACKOWIAK, PG [1 ]
机构
[1] HENRY FORD HOSP,DIV SURG PATHOL,DETROIT,MI 48202
关键词
COMPENSATION STANDARDS; FLOW CYTOMETRY; HISTOGRAM RESOLUTION; SPECTRAL OVERLAP; SPURIOUS ANEUPLOIDY; 2-COLOR DNA ANALYSIS;
D O I
10.1093/ajcp/101.5.630
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Spectral overlap of green fluorescence signals into the red detector (red-minus-green compensation) is one potential source of variation in two-color flow cytometric DNA analysis. Suboptimal compensation in a two-color propidium iodide (PI)/fluorescein isothiocyanate (FITC) system may be observed if compensation is adjusted using an inappropriate standard, or if changes to fluorescence detector high-voltage settings are made without corresponding readjustment of fluorescence compensation. To quantitate the influence of red-minus-green compensation on the quality of DNA histograms, data from 60 dual PI/cytokeratin (CK)-FITC stained carcinomas were acquired in parallel using two compensation standards: a PI/CK-FITC-stained T24 cell line calibrator overstained to achieve a high-intensity green fluorescence standard (HIGFS) with manually set compensation and automated compensation settings derived from commercial phycoerythrin/low intensity FITC beads (LIGF). Both compensation standards gave similar DNA hyperdiploidy results (DNA index, 1.1-2.8). However, LIGF standard yielded two falsely hypodiploid peaks (DNA index, .7 and .9). Eight left-skewed peaks became DNA diploid and symmetric, respectively, with the HIGFS. Use of HIGFS lowered the coefficient of variation percentage in 95% of cases, the greatest differences (maximum, 3.4%; mean, 1.81%) in tumors of highest intensity CK-FITC. The authors concluded that use of cell-based compensation standards (HIGFS) with intense green signals that mimic clinical tumor samples will avoid spurious aneuploidy and maximize resolution of near-diploid abnormalities.
引用
收藏
页码:630 / 637
页数:8
相关论文
共 50 条
  • [1] RAPID (ONE-SHOT) STAINING METHOD FOR 2-COLOR MULTIPARAMETRIC DNA FLOW CYTOMETRIC ANALYSIS OF CARCINOMAS USING STAINING FOR CYTOKERATIN AND LEUKOCYTE COMMON ANTIGEN
    ZARBO, RJ
    BROWN, RD
    LINDEN, MD
    TORRES, FX
    NAKHLEH, RE
    SCHULTZ, DS
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 101 (05) : 638 - 642
  • [2] THYMUS-CELLS IN MYASTHENIA-GRAVIS - A 2-COLOR FLOW CYTOMETRIC ANALYSIS OF LYMPHOCYTES IN THE THYMUS AND THYMOMA
    FUJII, Y
    HAYAKAWA, M
    NAKAHARA, K
    JOURNAL OF NEUROLOGY, 1992, 239 (02) : 82 - 88
  • [3] A method for flow cytometric analysis of Candida albicans DNA
    Stöver, AG
    Witek-Janusek, L
    Mathews, HL
    JOURNAL OF MICROBIOLOGICAL METHODS, 1998, 33 (03) : 191 - 196
  • [4] 2-COLOR IMMUNOFLUORESCENCE AND FLOW CYTOMETRIC ANALYSIS OF LAMINA PROPRIA LYMPHOCYTE SUBSETS IN ULCERATIVE-COLITIS AND CROHNS-DISEASE
    SENJU, M
    WU, KC
    MAHIDA, YR
    JEWELL, DP
    DIGESTIVE DISEASES AND SCIENCES, 1991, 36 (10) : 1453 - 1458
  • [5] FLOW CYTOMETRIC DNA ANALYSIS OF BREAST-CANCER BY 2 COLOR METHOD USING CYTOKERATIN LABELING FOR IDENTIFICATION OF TUMOR-CELLS
    KIMMIG, R
    SPELSBERG, H
    KAPSNER, T
    UNTCH, M
    HEPP, H
    ANALYTICAL CELLULAR PATHOLOGY, 1994, 7 (03): : 205 - 215
  • [6] DNA FLOW CYTOMETRIC ANALYSIS OF HEMANGIOPERICYTOMA
    FINN, WG
    GOOLSBY, CL
    SAMBASIVA, M
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 101 (02) : 181 - 185
  • [7] 2-COLOR FLOW CYTOMETRIC ANALYSIS OF NATURAL-KILLER AND CYTOTOXIC LYMPHOCYTE-T SUBSETS IN PERIPHERAL-BLOOD OF NORMAL HUMAN NEONATES
    SLUKVIN, II
    CHERNISHOV, VP
    BIOLOGY OF THE NEONATE, 1992, 61 (03): : 156 - 161
  • [8] 3-MARKER PHENOTYPIC ANALYSIS OF LYMPHOCYTES BASED ON 2-COLOR IMMUNOFLUORESCENCE USING A MULTINOMIAL MODEL FOR FLOW CYTOMETRIC COUNTS AND MAXIMUM-LIKELIHOOD-ESTIMATION
    VANPUTTEN, WLJ
    KORTBOYER, J
    BOLHUIS, RLH
    GRATAMA, JW
    CYTOMETRY, 1993, 14 (02): : 179 - 187
  • [9] FLOW CYTOMETRIC DNA ANALYSIS IN GYNECOLOGICAL ONCOLOGY
    VANDAM, PA
    WATSON, JV
    LOWE, DG
    SHEPHERD, JH
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 1992, 2 (02) : 57 - 65
  • [10] Flow cytometric DNA analysis of abnormal endometrium
    Sato, S
    Tanoguchi, K
    Tase, T
    Yajima, A
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1996, 178 (02) : 199 - 202