Low Dose versus Standard Single Heartbeat Acquisition Coronary Computed Tomography Angiography

被引:1
作者
Di Cesare, Ernesto [1 ]
Di Sibio, Alessandra [1 ]
Gennarelli, Antonio [1 ]
Di Luzio, Margherita [1 ]
Casazza, Ines [2 ]
Splendiani, Alessandra [1 ]
Di Cesare, Annamaria [1 ]
Gravina, Giovanni Luca [1 ]
Barile, Antonio [1 ]
Masciocchi, Carlo [1 ]
机构
[1] Univ Aquila, Dept Biotechnol & Appl Clin Sci, Via Vetoio 1, I-67100 Laquila, Italy
[2] Sapienza Univ, St Andrea Hosp, Dept Radiol, Rome, Italy
关键词
Coronary computed tomography angiography; image noise; image quality; radiation dose;
D O I
10.4103/jcis.JCIS_51_18
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to compare image quality and mean radiation dose between two groups of patients undergoing coronary computed tomography angiography (CCTA) using a 640-slice CT scanner with two protocols with different noise level thresholds expressed as standard deviation (SD). Materials and Methods: Two-hundred and sixty-eight patients underwent a CCTA with 640 slice CT scanner. In the experimental group (135 patients), an SD 51 protocol was employed; in the control group (133 patients), an SD 33 protocol was used. Mean effective dose and image quality with both objective and subjective measures were assessed. Image quality was subjectively assessed using a five-point scoring system. Segments scoring 2, 3, and 4 were considered having diagnostic quality, while segments scoring 0 and 1 were considered having nondiagnostic quality. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between the two groups as well as the effective radiation dose (ED) was finally assessed. Results: Comparative analysis considering diagnostic quality (2, 3, and 4 score) and nondiagnostic (score 0 and 1) quality demonstrated that image quality of SD 51 group is not significantly lower than that of S33 group. The noise was significantly higher in the SD 51 group than in the SD 33 group (P < 0.0001). The SNR and CNR were higher in the SD 33 group than in SD 51 group (P < 0.0001). Mean effective dose was 49% lower in the SD 51 group than in SD 33 group; indeed mean effective dose was 1.43 mSv +/- 0.67 in the SD 51 group while it was 2.8 mSv +/- 0.57 in the SD 33 group. Conclusion: Comparative analysis shows that using a 640-slice CT with a 51 SD protocol, it is possible to reduce the mean radiation dose while maintaining good diagnostic image quality.
引用
收藏
页数:7
相关论文
共 23 条
  • [1] [Anonymous], 2007, Ann ICRP, V37, P1, DOI 10.1016/j.icrp.2008.08.001
  • [2] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Bittencourt, Marcio Sommer
    Schmidt, Bernhard
    Seltmann, Martin
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner Guenther
    Achenbach, Stephan
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1081 - 1087
  • [3] Bongartz G., 2004, EUROPEAN GUIDELINES
  • [4] Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography
    Chun, Eun Ju
    Lee, Whal
    Choi, Young Hoon
    Koo, Bon-Kwon
    Choi, Sang Il
    Jae, Hwan Jun
    Kim, Hyo-Cheol
    So, Young Ho
    Chung, Jin Wook
    Park, Jae Hyung
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (01) : 86 - 92
  • [5] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46
  • [6] Di Cesare E, 2013, RADIOL MED, V118, P752, DOI 10.1007/s11547-012-0899-2
  • [7] Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM)
    di Cesare, E.
    Carbone, I.
    Carriero, A.
    Centonze, M.
    De Cobelli, F.
    De Rosa, R.
    Di Renzi, P.
    Esposito, A.
    Faletti, R.
    Fattori, R.
    Francone, M.
    Giovagnoni, A.
    La Grutta, L.
    Ligabue, G.
    Lovato, L.
    Marano, R.
    Midiri, M.
    Natale, L.
    Romagnoli, A.
    Russo, V.
    Sardanelli, F.
    Cademartiri, F.
    [J]. RADIOLOGIA MEDICA, 2012, 117 (06): : 901 - 938
  • [8] 320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure
    Di Cesare, Ernesto
    Gennarelli, Antonio
    Di Sibio, Alessandra
    Felli, Valentina
    Perri, Marco
    Splendiani, Alessandra
    Gravina, Giovanni Luca
    Barile, Antonio
    Masciocchi, Carlo
    [J]. RADIOLOGIA MEDICA, 2016, 121 (08): : 618 - 625
  • [9] Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis
    Di Cesare, Ernesto
    Gennarelli, Antonio
    Di Sibio, Alessandra
    Felli, Valentina
    Splendiani, Alessandra
    Gravina, Giovanni Luca
    Masciocchi, Carlo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (04) : 631 - 636
  • [10] Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis
    Di Cesare, Ernesto
    Gennarelli, Antonio
    Di Sibio, Alessandra
    Felli, Valentina
    Splendiani, Alessandra
    Gravina, Giovanni Luca
    Barile, Antonio
    Masciocchi, Carlo
    [J]. RADIOLOGIA MEDICA, 2014, 119 (08): : 642 - 649