OPTICAL DESIGN AND PERFORMANCE OF THE X25 HYBRID WIGGLER BEAM LINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE

被引:30
作者
BERMAN, LE
HASTINGS, JB
OVERSLUIZEN, T
WOODLE, M
机构
[1] National Synchrotron Light Source, Brookhaven National Laboratory, Upton
关键词
D O I
10.1063/1.1142721
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The X25 beam line at the National Synchrotron Light Source (NSLS) began full-power commissioning in 1990. It extracts radiation from a 27 pole hybrid wiggler, which produces up to 1.8 kW of total power with a peak horizontal density of 450 W/mrad and critical energy of 4.6 keV. The design and peformance of the beam line optics are described, in particular, the cooling of the first monochromator crystal.
引用
收藏
页码:428 / 432
页数:5
相关论文
共 25 条
[1]  
BERMAN L, UNPUB
[2]  
Berman L. E., 1991, SYNCH RAD NEWS, V4, P22
[3]   PERFORMANCE OF WATER JET COOLED SILICON MONOCHROMATORS ON A MULTIPOLE WIGGLER BEAM LINE AT NSLS [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02) :415-421
[4]   ADAPTIVE CRYSTAL OPTICS FOR HIGH-POWER SYNCHROTRON SOURCES [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (03) :558-562
[5]  
BERMAN LE, 1992, REV SCI INS, V63
[6]   THE PERFORMANCE OF A SEPARATED CRYSTAL X-RAY MONOCHROMATOR DURING WIGGLER HEATING - PRELIMINARY-RESULTS [J].
BILDERBACK, DH ;
MILLS, DM ;
BATTERMAN, BW ;
HENDERSON, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :428-433
[7]   MAGNETIC MEASUREMENTS ON INSERTION DEVICES AT NSLS [J].
DECKER, G ;
GALAYDA, J ;
SOLOMON, L ;
KITAMURA, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1845-1848
[8]  
GMUR N, 1991, 435 NAT SYNCHR LIGHT
[9]   ELIMINATION OF THE INNER-SHELL LIFETIME BROADENING IN X-RAY-ABSORPTION SPECTROSCOPY [J].
HAMALAINEN, K ;
SIDDONS, DP ;
HASTINGS, JB ;
BERMAN, LE .
PHYSICAL REVIEW LETTERS, 1991, 67 (20) :2850-2853
[10]   X-RAY MONOCHROMATORS FOR HIGH-POWER SYNCHROTRON RADIATION SOURCES [J].
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2) :306-311