Accuracy of Rapid Point-of-Care Diagnostic Tests for Hepatitis B Surface Antigen-A Systematic Review and Meta-analysis

被引:32
|
作者
Khuroo, Mehnaaz S. [1 ]
Khuroo, Naira S. [2 ]
Khuroo, Mohammad S. [2 ]
机构
[1] Govt Med Coll Srinagar, Dr Khuroo Med Clin, Kashmir 190010, Jammu & Kashmir, India
[2] Digest Dis Ctr, Dr Khuroo Med Clin, Kashmir 190010, Jammu & Kashmir, India
关键词
HBsAg; rapid test; performance evaluation; meta-analysis;
D O I
10.1016/j.jceh.2014.07.008
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Rapid point-of-care tests provide plausible diagnostic strategy for hepatitis B surface antigen (HBsAg) in low resource areas. However, their utility depends upon their overall performance. Our objective was to meta-analyze the diagnostic accuracy of rapid point-of-care tests for HBsAg. Methods: Literature search was done with the help of a metasearch engine Metta, a query interface for retrieving articles from five leading medical databases. Studies that employed rapid point-of-care tests for detection of HBsAg and compared the results with reference test were included. Two reviewers performed quality assessment of the studies and extracted data for estimating test accuracy. Twenty-seven studies were meta-analyzed and stratified by multiple parameters. Results: Twenty-seven studies had evaluated 49 test brands and generated 76 data points. Sensitivity of individual tests varied widely and were heterogeneous (range 43.5%-99.8%); while specificity estimates were more robust and close to 100% (range 90%-100%). Overall pooled sensitivity, specificity, positive likelihood ratio (LR), negative LR and diagnostic odds ratio for all tests were 97.1% (95% CI, 96.1%-97.9%), 99.9% (CI, 99.8%-100%), 118.4 (CI, 84.7-165.5), 0.032 (CI, 0.023-0.045) and 4094.7 (CI, 2504.1-6600.8) respectively. This suggested high pooled accuracy for all studies. We found substantial heterogeneity between studies. Three factors (study location, reference standard and study score) appeared most strongly associated with test estimates and observed heterogeneity. The Determine test showed consistency in performance in studies done across developed and developing countries and the Determine and the BinaxNOW tests had significantly higher estimates than pooled estimates of remaining tests. Tests revealed analytical sensitivity of 4 IU/ml against manufacturer's claim of 0.5 IU/ml; reduced sensitivity with HBsAg mutants and poor performance in seroconversion panels. Conclusions: Tests with better analytical sensitivity need to be developed and their feasibility and outcomes in various clinical settings need to be addressed.
引用
收藏
页码:226 / 240
页数:15
相关论文
共 50 条
  • [31] Point-of-Care Tests for Rapid Detection of Porcine Epidemic Diarrhea Virus: A Systematic Review and Meta-Analysis
    Li, Renfeng
    Tian, Xiangqin
    Pang, Junzeng
    Li, Linyue
    Yuan, Jiakang
    Tian, Zhuangzhuang
    Wang, Ziliang
    VIRUSES-BASEL, 2022, 14 (07):
  • [32] Impact of point-of-care panel tests in ambulatory care: a systematic review and meta-analysis
    Goyder, Clare
    Tan, Pui San
    Verbakel, Jan
    Ananthakumar, Thanusha
    Lee, Joseph J.
    Hayward, Gail
    Turner, Philip J.
    Van Den Bruel, Ann
    BMJ OPEN, 2020, 10 (02):
  • [33] Impact of point-of-care tests in community pharmacies: a systematic review and meta-analysis
    Albasri, Ali
    Van den Bruel, Ann
    Hayward, Gail
    McManus, Richard J.
    Sheppard, James Peter
    Verbakel, Jan Yvan Jos
    BMJ OPEN, 2020, 10 (05):
  • [34] Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta-analysis
    Chartrand, Caroline
    Tremblay, Nicolas
    Renaud, Christian
    Papenburg, Jesse
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (12) : 3738 - 3749
  • [35] Accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection: systematic review and meta-analysis
    Danso-Appiah, Anthony
    Minton, Jonathan
    Boamah, Daniel
    Otchere, Joseph
    Asmah, Richard H.
    Rodgers, Mark
    Bosompem, Kwabena M.
    Eusebi, Paolo
    De Vlas, Sake J.
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2016, 94 (07) : 522 - 533
  • [36] DIAGNOSTIC ACCURACY OF RAPID POINT-OF-CARE TESTS TO DETECT SYPHILIS: A META-ANALYSES
    Jafari, Y.
    Peeling, R.
    Shivkumar, S.
    Lambert, G.
    Claessens, C.
    Cajas, J.
    Klein, M.
    Joseph, L.
    Pai, N.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A71 - A71
  • [37] Point-of-care diagnostic test accuracy in children and adolescents with sickle cell disease: A systematic review and meta-analysis
    Bagnall, Robert
    Guy, Danielle
    Morgan, Rebecca L.
    Babatunde, Ifeoluwa
    Neviere, Agathe
    Friedrich, Gabriela
    Bennetts, Liga
    Irfan, Omar
    Odame, Isaac
    BLOOD REVIEWS, 2025, 69
  • [38] Diagnostic Accuracy of Point-of-Care Ultrasound (POCUS) in Patients With Respiratory Tract Disorders - A Systematic Review and Meta-analysis
    Malik, F. A.
    Raheem, A.
    Selvam, S.
    Patel, U. K.
    Mahmood, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [39] Glucose Testing Methods: A Systematic Review and Meta-Analysis of Diagnostic Accuracy of Point-of-Care Devices for Neonatal Hypoglycemia
    St Clair, Sophie L.
    Ulyatt, Caitlyn M.
    Corkin, Maria T.
    Lord, Libby G.
    Crowther, Caroline A.
    Harding, Jane E.
    Lin, Luling
    JOURNAL OF PEDIATRICS, 2024, 278
  • [40] Diagnostic Accuracy of Point-of-Care HCV Viral Load Assays for HCV Diagnosis: A Systematic Review and Meta-Analysis
    Tang, Weiming
    Tao, Yusha
    Fajardo, Emmanuel
    Reipold, Elena Ivanova
    Chou, Roger
    Tucker, Joseph D.
    Easterbrook, Philippa
    DIAGNOSTICS, 2022, 12 (05)