THE MICROBIOLOGICAL QUALITY OF WATER IN DENTAL CHAIR UNITS

被引:40
作者
PANKHURST, CL [1 ]
PHILPOTTHOWARD, JN [1 ]
机构
[1] KINGS COLL,SCH MED & DENT,DEPT MED MICROBIOL,LONDON SE5 8RX,ENGLAND
关键词
WATER MICROBIOLOGY; LEGIONELLA; WATER SUPPLY; DENTAL CLINICS; DISINFECTION;
D O I
10.1016/0195-6701(93)90022-R
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Infection control is an important issue in the dental surgery but the potential hazards associated with contaminated dental water have received relatively little attention in recent years. The complex design of the equipment results in stagnation of water within the dental chair and subsequent amplification of contaminating environmental organisms, including pseudomonads and legionellae, to potentially hazardous levels. Immunocompromised patients may be at particular risk of infection. Very poor water quality with total bacterial counts above 104 ml-1 is unpleasant for all patients, and the dental chair supply should be of drinking water quality. In addition to these problems, bacteria and viruses may be aspirated from the oral cavity and contaminate the handpiece. Measures to reduce microbial contamination of dental chairs and equipment include flushing water through the chair's equipment at the beginning of each day; continuous or pulsed water chlorination, or application of biocides other than chlorine; provision of sterile bottled water in the system; and autoclaving handpieces between patients. Future dental chair design must attempt to resolve the problems associated with microbial contamination of the water supply and aerosols generated during dental procedures. © 1993.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [31] Microbiological analysis of mineral water and drinking water of reservoir supplies, Brazil
    Alves, NC
    Odorizzi, AC
    Goulart, FC
    REVISTA DE SAUDE PUBLICA, 2002, 36 (06): : 749 - 751
  • [32] Effective control of dental chair unit waterline biofilm and marked reduction of bacterial contamination of output water using two peroxide-based disinfectants
    Tuttlebee, CM
    O'Donnell, MJ
    Keane, CT
    Russell, RJ
    Sullivan, DJ
    Falkiner, F
    Coleman, DC
    JOURNAL OF HOSPITAL INFECTION, 2002, 52 (03) : 192 - 205
  • [33] The microbiological load and microbiome of the Dutch dental unit; 'please, hold your breath'
    Hoogenkamp, Michel A.
    Brandt, Bernd W.
    Laheij, Alexa M. G. A.
    de Soet, Johannes J.
    Crielaard, Wim
    WATER RESEARCH, 2021, 200
  • [34] Factors affecting microbiological quality of household drinking water supplied by small-scale ultrafiltration systems: A field study
    Zhang, Xiaolei
    He, Yankun
    Zhang, Beichen
    Qin, Lanlan
    Yang, Qing
    Huang, Haiou
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 689 : 725 - 733
  • [35] Effect of Inter-Observer Variation on the Association between Contamination Hazards and the Microbiological Quality of Water Sources: A Longitudinal Study
    Okotto-Okotto, Joseph
    Trajano Gomes da Silva, Diogo
    Kwoba, Emmah
    Thumbi, Samuel. M.
    Wanza, Peggy
    Yu, Weiyu
    Wright, Jim A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (24) : 1 - 15
  • [36] Investigations on microbiological quality of ground, tap and drinking water in livestock with regard to watering management and treatment with a modified peracetic acid
    Visscher, C. F.
    Kuemmel, Ulrike
    Taube, Venja
    Guenther, R.
    Verkaar, E. L.
    Siesenop, Ute
    Reich, F.
    Beyerbach, M.
    Kamphues, J.
    ARCHIV FUR GEFLUGELKUNDE, 2010, 74 (01): : 62 - 71
  • [37] EFFECT OF ULTRAVIOLET RADIATIONS ON THE MICROBIOLOGICAL QUALITY OF DRINKABLE GROUNDWATER
    Zagan, Sabina
    Negreanu-Pirjol, Bogdan
    Negreanu-Pirjol, Ticuta
    Gorun, Elena
    Zagan, Remus
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2011, 10 (11): : 1687 - 1692
  • [38] Failure to eradicate non-tuberculous mycobacteria upon disinfection of heater-cooler units: results of a microbiological investigation in northwestern Italy
    Ditommaso, S.
    Giacomuzzi, M.
    Memoli, G.
    Zotti, C. M.
    JOURNAL OF HOSPITAL INFECTION, 2020, 106 (03) : 585 - 593
  • [39] Electrochemical Water Treatment for the Suppression of the Development of Microbiological Contamination in Technical Water Systems
    Sivolobova, N. O.
    Gracheva, N., V
    Zheltobryukhov, F., V
    Selezneva, N. A.
    Dorodnikova, I. M.
    ALL-RUSSIAN RESEARCH-TO-PRACTICE CONFERENCE ECOLOGY AND SAFETY IN THE TECHNOSPHERE: CURRENT PROBLEMS AND SOLUTIONS, 2020, 543
  • [40] Microbiological Contaminants in Drinking Water: Current Status and Challenges
    Kristanti, Risky Ayu
    Hadibarata, Tony
    Syafrudin, Muhammad
    Yilmaz, Murat
    Abdullah, Shakila
    WATER AIR AND SOIL POLLUTION, 2022, 233 (08)