THE MICROBIOLOGICAL QUALITY OF WATER IN DENTAL CHAIR UNITS

被引:40
|
作者
PANKHURST, CL [1 ]
PHILPOTTHOWARD, JN [1 ]
机构
[1] KINGS COLL,SCH MED & DENT,DEPT MED MICROBIOL,LONDON SE5 8RX,ENGLAND
关键词
WATER MICROBIOLOGY; LEGIONELLA; WATER SUPPLY; DENTAL CLINICS; DISINFECTION;
D O I
10.1016/0195-6701(93)90022-R
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Infection control is an important issue in the dental surgery but the potential hazards associated with contaminated dental water have received relatively little attention in recent years. The complex design of the equipment results in stagnation of water within the dental chair and subsequent amplification of contaminating environmental organisms, including pseudomonads and legionellae, to potentially hazardous levels. Immunocompromised patients may be at particular risk of infection. Very poor water quality with total bacterial counts above 104 ml-1 is unpleasant for all patients, and the dental chair supply should be of drinking water quality. In addition to these problems, bacteria and viruses may be aspirated from the oral cavity and contaminate the handpiece. Measures to reduce microbial contamination of dental chairs and equipment include flushing water through the chair's equipment at the beginning of each day; continuous or pulsed water chlorination, or application of biocides other than chlorine; provision of sterile bottled water in the system; and autoclaving handpieces between patients. Future dental chair design must attempt to resolve the problems associated with microbial contamination of the water supply and aerosols generated during dental procedures. © 1993.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] Impact of Chlorine Dioxide on Pathogenic Waterborne Microorganisms Occurring in Dental Chair Units
    Krueger, Theresa Isabella Maria
    Herzog, Susann
    Mellmann, Alexander
    Kuczius, Thorsten
    MICROORGANISMS, 2023, 11 (05)
  • [2] Testing for aerobic heterotrophic bacteria allows no prediction of contamination with potentially pathogenic bacteria in the output water of dental chair units
    Bristela, Margit
    Skolka, Astrid
    Martina
    Schmid-Schwap
    Piehslinger, Eva
    Indra, Alexander
    Wewalka, Guenther
    Stauffer, Fritz
    GMS HYGIENE AND INFECTION CONTROL, 2012, 7 (01):
  • [3] Disinfection of Dental Chair Water Using Aqueous Chlorine Dioxide
    Wei, Li-Lin
    Hu, Chan-Chih
    Hsu, Chu-Wei
    Pen, Chun-Wei
    Chen, Li-Yu
    Yu, Yu-Chun
    Carey, James R.
    Yin, Hao-Chang
    Wang, Shan-Shue
    WATER, 2021, 13 (23)
  • [4] Occurrence and prevalence of Legionella species in dental chair units in Germany with a focus on risk factors
    Optenhoevel, Marleen
    Mellmann, Alexander
    Kuczius, Thorsten
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (10) : 1235 - 1244
  • [5] MICROBIOLOGICAL ASPECTS OF WATER-QUALITY AND HEALTH
    DADSWELL, JV
    JOURNAL OF THE INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1990, 4 (06): : 515 - 519
  • [6] An Evaluation of Two Systems for the Management of the Microbiological Quality of Water in Dental Unit Waterlines: Hygowater(R) and IGN Calbenium(R)
    Offner, Damien
    Musset, Anne-Marie
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)
  • [8] MICROBIOLOGICAL QUALITY OF RESIDUES FROM DRINKING-WATER PREPARATION
    WURZER, M
    WIEDENMANN, A
    BOTZENHART, K
    WATER SCIENCE AND TECHNOLOGY, 1995, 31 (5-6) : 75 - 79
  • [9] Microbial quality of water in dental unit reservoirs
    Szymanska, J
    Wdowiak, L
    Puacz, E
    Stojek, NM
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2004, 11 (02) : 355 - 358
  • [10] Microbiological contamination of Dental Unit Water Systems in general practices from Barcelona (Spain)
    Araujo, R
    Contreras, N
    WATERBORNE PATHOGENS, 2004, 4 (02): : 1 - 5