THE SPATIAL LOCATION OF EEG ELECTRODES - LOCATING THE BEST-FITTING SPHERE RELATIVE TO CORTICAL ANATOMY

被引:295
作者
TOWLE, VL
BOLANOS, J
SUAREZ, D
TAN, K
GRZESZCZUK, R
LEVIN, DN
CAKMUR, R
FRANK, SA
SPIRE, JP
机构
[1] BRAIN RES FDN, CHICAGO, IL USA
[2] DOKUZ EYLOL UNIV, IZMIR, TURKEY
[3] UNIV CHICAGO, DEPT RADIOL, CHICAGO, IL 60637 USA
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1993年 / 86卷 / 01期
关键词
EVOKED POTENTIALS (EP); EEG DIPOLE LOCALIZATION METHODS (DLM); 10-20; SYSTEM; BRAIN FUNCTION;
D O I
10.1016/0013-4694(93)90061-Y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The location of the international 10-20 system electrode positions and 14 fiducial landmarks are described in cartesian coordinates (+/- 1.4 mm average accuracy). Six replications were obtained on 3 separate days from 4 normal subjects, who were compared to each other with a best-fit sphere algorithm. Test-retest reliability depended on the electrode position: the parasagittal electrodes were associated with greater measurement errors (maximum 7 mm) than midline locations. Location variability due to head shape was greatest in the temporal region, averaging 5 mm from the mean. For each subject's electrode locations a best-fitting sphere was determined (79-87 mm radius, 6% average error). A surface-fitting algorithm was used to transfer the electrode locations and best-fitting sphere to MR images of the brain and scalp. The center of the best-fitting sphere coincided with the floor of the third ventricle 5 mm anterior to the posterior commissure. The melding of EEG electrode location information with brain anatomy provides an empirical basis for associating hypothetical equivalent dipole locations with their anatomical substrates.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 32 条
  • [1] PRACTICAL CONSIDERATIONS IN THE POSITIONING OF EEG ELECTRODES
    BINNIE, CD
    DEKKER, E
    SMIT, A
    VANDERLINDEN, G
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1982, 53 (04): : 453 - 458
  • [2] ANATOMIC CORRELATES OF 10-20 ELECTRODE PLACEMENT SYSTEM IN INFANTS
    BLUME, WT
    BUZA, RC
    OKAZAKI, H
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1974, 36 (03): : 303 - 307
  • [3] BLUMENHARDT LD, 1979, EXP BRAIN RES, V36, P53
  • [4] BRINDLEY GS, 1972, J PHYSIOL-LONDON, V225, pP1
  • [5] MODIFIED NOMENCLATURE FOR THE 10-PERCENT ELECTRODE SYSTEM
    CHATRIAN, GE
    LETTICH, E
    NELSON, PL
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1988, 5 (02) : 183 - 186
  • [6] EFFECTS OF HEAD SHAPE ON EEGS AND MEGS
    CUFFIN, BN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) : 44 - 52
  • [7] COMPUTER-ASSISTED PLACEMENT OF ELECTRODES ON THE HUMAN HEAD
    ECHALLIER, JF
    PERRIN, F
    PERNIER, J
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (02): : 160 - 163
  • [8] HUMAN BRAIN - LEFT-RIGHT ASYMMETRIES IN TEMPORAL SPEECH REGION
    GESCHWIND, N
    LEVITSKY, W
    [J]. SCIENCE, 1968, 161 (3837) : 186 - +
  • [9] Gevins A S, 1991, Ann N Y Acad Sci, V620, P22, DOI 10.1111/j.1749-6632.1991.tb51572.x
  • [10] GRZESZCZUK R, 1990, RADIOLOGY P, V177, P290