MICRON-RESOLUTION RANGING OF CORNEA ANTERIOR-CHAMBER BY OPTICAL REFLECTOMETRY

被引:109
作者
HUANG, D
WANG, JP
LIN, CP
PULIAFITO, CA
FUJIMOTO, JG
机构
[1] MIT,DEPT ELECT ENGN & COMP SCI,36-361,CAMBRIDGE,MA 02139
[2] MIT,ELECTR RES LAB,CAMBRIDGE,MA 02139
[3] HARVARD UNIV,SCH MED,DEPT OPHTHALMOL,BOSTON,MA 02115
[4] MASSACHUSETTS EYE & EAR HOSP,LASER RES LAB,BOSTON,MA 02114
关键词
CORNEAL TOPOGRAPHY; KERATOREFRACTIVE SURGERY; OPTICAL RANGING; BIOMETRY; ANTERIOR CHAMBER DEPTH;
D O I
10.1002/lsm.1900110506
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Noncontact, high resolution measurements of anterior eye structures using optical coherence domain reflectometry are described. Distances between intraocular structures are measured by directing a beam of short coherence length light onto the eye and performing an interferometric measurement on the optical group delay of reflected signals. Measurements of corneal thickness, corneal excision depth, and anterior chamber depth are demonstrated in vitro, and the location of tissue boundaries is resolved to within +/- 2-mu-m. The full-width-half-maximum longitudinal resolution is 10-mu-m. Sensitivities to reflected signals as small as 10(-10) of the incident power are achieved by heterodyne detection.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 18 条
  • [1] OPTICAL REFLECTOMETRY WITH MICROMETER RESOLUTION FOR THE INVESTIGATION OF INTEGRATED OPTICAL-DEVICES
    BEAUD, P
    SCHUTZ, J
    HODEL, W
    WEBER, HP
    GILGEN, HH
    SALATHE, RP
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1989, 25 (04) : 755 - 759
  • [2] COTLIAR AM, 1985, OPHTHALMOLOGY, V92, P206
  • [3] EHLERS N, 1971, ACTA OPHTHALMOL, V49, P65
  • [4] WOUND-HEALING AFTER EXCIMER LASER KERATOMILEUSIS (PHOTOREFRACTIVE KERATECTOMY) IN MONKEYS
    FANTES, FE
    HANNA, KD
    WARING, GO
    POULIQUEN, Y
    THOMPSON, KP
    SAVOLDELLI, M
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (05) : 665 - 675
  • [5] EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT
    FERCHER, AF
    MENGEDOHT, K
    WERNER, W
    [J]. OPTICS LETTERS, 1988, 13 (03) : 186 - 188
  • [6] FEMTOSECOND OPTICAL RANGING IN BIOLOGICAL-SYSTEMS
    FUJIMOTO, JG
    DESILVESTRI, S
    IPPEN, EP
    PULIAFITO, CA
    MARGOLIS, R
    OSEROFF, A
    [J]. OPTICS LETTERS, 1986, 11 (03) : 150 - 152
  • [7] VARIABILITY OF ULTRASONIC PACHOMETRY
    GORDON, A
    BOGGESS, EA
    MOLINARI, JF
    [J]. OPTOMETRY AND VISION SCIENCE, 1990, 67 (03) : 162 - 165
  • [8] CORNEAL THICKNESS MEASURED BY INTERFEROMETRY
    GREEN, DG
    FRUEH, BR
    SHAPIRO, JM
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1975, 65 (02) : 119 - 123
  • [9] HITZENBERGER CK, 1991, INVEST OPHTH VIS SCI, V32, P616
  • [10] Marshall J, 1986, LASERS OPHTHALMOL, V1, P21