OPTIMIZATION STRATEGIES IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY - ONE-PARAMETER OPTIMIZATIONS OF THE CONCENTRATION OF SODIUM DODECYL-SULFATE AND THE CONCENTRATION OF MODIFIERS (UREA AND GLUCOSE)

被引:27
作者
PYELL, U
BUTEHORN, U
机构
[1] Fachbereich Chemie der Philipps-Universität Marburg, Marburg, 35032, Hans-Meerwein-Straße
关键词
CAPILLARY ELECTROPHORESIS; CRITICAL MICELLE CONCENTRATION; RETENTION FACTORS; MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY; METHYLNITROANILINES;
D O I
10.1007/BF02272168
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 27 条
[1]   EFFECTS OF 1-ALKANOLS ON SEPARATION PERFORMANCE IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
AIKEN, JH ;
HUIE, CW .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (02) :95-99
[2]   GRADIENT ELUTION FOR MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
BALCHUNAS, AT ;
SEPANIAK, MJ .
ANALYTICAL CHEMISTRY, 1988, 60 (07) :617-621
[3]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY WITH CATIONIC SURFACTANTS [J].
CROSBY, D ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10) :2161-2187
[4]   OPTIMIZATION OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY [J].
FOLEY, JP .
ANALYTICAL CHEMISTRY, 1990, 62 (13) :1302-1308
[5]  
GORSE J, 1988, HRC-J HIGH RES CHROM, V11, P554
[6]   EFFECT OF ADDITION OF GLUCOSE ON MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY WITH SODIUM DODECYL-SULFATE [J].
KANETA, T ;
TANAKA, S ;
TAGA, M ;
YOSHIDA, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :369-374
[7]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF ACIDIC SOLUTES - MIGRATION BEHAVIOR AND OPTIMIZATION STRATEGIES [J].
KHALEDI, MG ;
SMITH, SC ;
STRASTERS, JK .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1820-1830
[8]  
KVIVINDEVOGEL J, 1991, HRC-J HIGH RES CHROM, V14, P795
[9]  
MUCKERJEE P, 1963, J PHYS CHEM-US, V67, P190
[10]  
MUKERJEE P, 1976, J PHARM SCI, V65, P882, DOI 10.1002/jps.2600650620