Detector Mount Design for IGRINS

被引:5
作者
Oh, Jae Sok [1 ]
Park, Chan [1 ]
Cha, Sang-Mok [1 ]
Yuk, In-Soo [1 ]
Park, Kwijong [1 ]
Kim, Kang-Min [1 ]
Chun, Moo-Young [1 ]
Ko, Kyeongyeon [1 ]
Oh, Heeyoung [1 ]
Jeong, Ueejeong [1 ]
Nah, Jakyoung [1 ]
Lee, Hanshin [2 ]
Jaffe, Daniel T. [3 ]
机构
[1] Korea Astron & Space Sci Inst, Daejeon 305348, South Korea
[2] Univ Texas Austin, McDonald Observ, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Astron, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
IGRINS; H2RG detector; detector mount; ASIC housing; flex cable; FFL; G10; support;
D O I
10.5140/JASS.2014.31.2.177
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Immersion Grating Infrared Spectrometer (IGRINS) is a near- infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 21 条
  • [1] Avallone Eugene A., 2007, MARKS STANDARD HDB M
  • [2] Barnes S, 2009, IGRINS OPTICAL DESIG, P13
  • [3] SUPPORT OF COOLED COMPONENTS IN ASTRONOMICAL INSTRUMENTS
    HASTINGS, PR
    MONTGOMERY, DM
    [J]. CRYOGENICS, 1993, 33 (11) : 1032 - 1036
  • [4] Helix Technology Corporation, 2002, PROD INF CTI CRY CRY
  • [5] Micromachined silicon diffraction gratings for infrared spectroscopy
    Jaffe, DT
    Keller, LD
    Ershov, O
    [J]. INFRARED ASTRONOMICAL INSTRUMENTATION, PTS 1-2, 1998, 3354 : 201 - 212
  • [6] Jaffe DT, 2011, IGRINS CRITICAL DESI
  • [7] Lee SH, 2010, IGRINS FUNCTIONAL PE
  • [8] LORD Corporation, 2004, DS3017 LORD CORP
  • [9] Marquardt ED, 2000, 11 INT CRY C
  • [10] Production and evaluation of silicon immersion gratings for infrared astronomy
    Marsh, J. P.
    Mar, D. J.
    Jaffe, D. T.
    [J]. APPLIED OPTICS, 2007, 46 (17) : 3400 - 3416