FLOW-INJECTION AMPEROMETRY OF CYSTEINE AND GLUTATHIONE AT AN ELECTRODE MODIFIED WITH A RUTHENIUM-CONTAINING INORGANIC FILM

被引:55
作者
COX, JA
GRAY, TJ
机构
[1] Department of Chemistry, Miami University, Oxford, Ohio
关键词
D O I
10.1002/elan.1140020205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A film that contains ruthenium oxide of mixed valences and cyanide (mvRuCN) on a glassy carbon electrode promotes the diffusion‐controlled oxidation of cysteine and glutathione at 0.92 V vs. Ag/AgCl. These mediated oxidations allow the determination of these thiols by flow‐injection amperometry in pH 2 solutions of 0.2 or 0.02 M K2SO4. Calibration curves are linear over about three orders of magnitude, and detection limits are in the submicromolar range with 7.5 μL injections. The sensitivity for cysteine is about 50 nA/μM with a flow rate of 1.0 mL/min. The throughput calculated on the basis of peak widths was 140 samples/h. Experimentally, with a manual injector, 60 samples/h were routinely analyzed. The sensitivity for glutathione in 0.2 M K2SO4 at pH 2 is somewhat lower, 36 nA/μM. A single electrode was used for hundreds of injections over a 2‐week period with no change in sensitivity. The mvRuCN‐coated electrode is operated in a potentiostatic mode; reactivation of the surface between series of experiments was not necessary. The electrode was stored at open circuit in contact with an electrolyte solution when not in use. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 26 条
[1]   LIQUID-CHROMATOGRAPHIC BEHAVIOR OF BIOLOGICAL THIOLS AND THE CORRESPONDING DISULFIDES [J].
ALLISON, LA ;
KEDDINGTON, J ;
SHOUP, RE .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (10) :1785-1798
[2]   DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[3]   DETERMINATION OF GLUTATHIONE IN BIOLOGICAL-MATERIAL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BUCHBERGER, W ;
WINSAUER, K .
ANALYTICA CHIMICA ACTA, 1987, 196 :251-254
[4]   HPLC DETERMINATION OF THIOL DRUGS IN PHARMACEUTICAL FORMULATIONS USING ETHACRYNIC-ACID AS A PRECOLUMN ULTRAVIOLET DERIVATIZATION REAGENT [J].
CAVRINI, V ;
GATTI, R ;
DIPIETRA, AM ;
RAGGI, MA .
CHROMATOGRAPHIA, 1987, 23 (09) :680-683
[5]   STABLE MODIFIED ELECTRODES FOR FLOW-INJECTION AMPEROMETRY - APPLICATION TO THE DETERMINATION OF THIOCYANATE [J].
COX, JA ;
GRAY, T ;
KULKARNI, KR .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1710-1713
[6]   ELECTROCATALYTIC OXIDATION AND DETERMINATION OF ARSENIC(III) ON A GLASSY-CARBON ELECTRODE MODIFIED WITH A THIN-FILM OF MIXED-VALENT RUTHENIUM(III, II) CYANIDE [J].
COX, JA ;
KULESZA, PJ .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :1021-1025
[7]  
COX JA, 1988, FEDERATION ANAL CHEM
[8]   ANALYSIS OF HEPATIC REDUCED GLUTATHIONE, CYSTEINE AND HOMOCYSTEINE BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
DEMASTER, EG ;
SHIROTA, FN ;
REDFERN, B ;
GOON, DJW ;
NAGASAWA, HT .
JOURNAL OF CHROMATOGRAPHY, 1984, 308 (JUN) :83-91
[9]   MEASUREMENT OF TISSUE SULFHYDRYLS AND DISULFIDES IN TISSUE PROTEIN AND NONPROTEIN FRACTIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION [J].
DUPUY, D ;
SZABO, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (01) :107-119
[10]   ELECTROCHEMICAL FLOW-THROUGH DETECTOR FOR DETERMINATION OF CYSTINE AND RELATED COMPOUNDS [J].
EGGLI, R ;
ASPER, R .
ANALYTICA CHIMICA ACTA, 1978, 101 (02) :253-259