Diagnosis of Carpal Tunnel Syndrome: Interobserver Reliability of the Blinded Scratch-Collapse Test

被引:20
作者
Blok, Robin D. [1 ]
Becker, Stephanie J. E. [1 ]
Ring, David C. [1 ]
机构
[1] Massachusetts Gen Hosp, Yawkey Ctr, Orthopaed Hand & Upper Extrem Serv, Suite 2100,55 Fruit St, Boston, MA 02114 USA
关键词
Scratch-collapse test; Interobserver reliability; Carpal tunnel syndrome;
D O I
10.1007/s12593-013-0105-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
The reliability of the scratch-collapse test for diagnosis of carpal tunnel syndrome (CTS) has not been tested by independent investigators. This study measured the reliability of the scratch-collapse test comparing the treating hand surgeon and blinded evaluators. We performed a prospective observational study of 41 patients with a provisional diagnosis of CTS or a combination of CTS and cubital tunnel syndrome and prescribed electrodiagnostic testing. The treating hand surgeon performed the scratch-collapse test. Next, the test was administered by one of the six observers, unaware of the patient's symptoms and the diagnosis made by treating hand surgeon. The kappa statistic (.) was used to calculate the interrater reliability between the treating hand surgeons and blinded scratchers. The agreement between the blinded observers and the hand surgeons on the scratch-collapse test was substantial 0.63 (95 % CI, 0.34-0.87; p < 0.001). The sensitivity of the blinded scratch test in our sample was 32 %. In a small study with a spectrum bias favoring electrophysiologically confirmed CTS the reliability was lower than that reported by the inventors of the test, but was still substantial. We propose a larger study of patients with a greater variety of electrodiagnostic test results using fewer observers with more experience.
引用
收藏
页码:5 / 7
页数:3
相关论文
共 50 条
[31]   The "biro test" for autonomic dysfunction in carpal tunnel syndrome [J].
Kumar, A. ;
Bismil, Q. ;
Morgan, B. ;
Ashbrooke, A. ;
Davies, S. ;
Solan, M. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (03) :355-357
[32]   A study of interpolation method in diagnosis of carpal tunnel syndrome [J].
Ashraf, Alireza ;
Daghaghzadeh, Abbas ;
Naseri, Mahshid ;
Nasiri, Aref ;
Fakheri, Maryam .
ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2013, 16 (04) :623-626
[33]   Ultrasonography of the Median Nerve in the Carpal Tunnel Syndrome Diagnosis [J].
Pertea, Mihaela ;
Ursu, S. ;
Ciobanu, P. ;
Grosu, Oxana Madalina ;
Tudor, R. ;
Sirbu, P. D. .
2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
[34]   Accuracy of Surgeon Diagnosis in Predicting Carpal Tunnel Syndrome [J].
D'Auria, Jennifer L. ;
Montanez, Anthony ;
Toirac, Alexander ;
Goitz, Robert J. ;
Fowler, John R. .
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (02) :179-182
[35]   The efficacy of neurophysiological examination in the diagnosis of carpal tunnel syndrome [J].
Madrazo, J ;
Marín, I ;
Bringas, A ;
Fernández, A .
REVISTA DE NEUROLOGIA, 2000, 30 (11) :1005-1008
[36]   Are Relieving Maneuvers Useful in Diagnosis of Carpal Tunnel Syndrome? [J].
Gok, Haydar ;
Ay, Saime ;
Kutlay, Sehim .
ROMATIZMA-RHEUMATISM, 2008, 23 (04) :129-134
[37]   Comparison of Interpolation Methods in the Diagnosis of Carpal Tunnel Syndrome [J].
Alcan, Veysel ;
Zinnuroglu, Murat ;
Karatas, Gulcin Kaymak ;
Bodofsky, Elliot .
BALKAN MEDICAL JOURNAL, 2018, 35 (05) :378-383
[38]   Carpal tunnel syndrome diagnosis as a risk factor for falls [J].
Lakhlani, Devi ;
Shahoumian, Troy A. ;
Curtin, Catherine .
INTERNATIONAL ORTHOPAEDICS, 2025, 49 (04) :805-812
[39]   Evaluation of electrophysiological examinations for the diagnosis of carpal tunnel syndrome [J].
Chen, Xi ;
Cao, Jinjin ;
Lao, Jie ;
Liu, Ailin ;
Rui, Jing .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01)
[40]   Diagnostic accuracy of ultrasonography in diagnosis of Carpal Tunnel Syndrome [J].
Shaukat, Aamir ;
Aamir, Hooria ;
Ahmad, Zaheer ;
Ahmad, Umair .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (04) :753-756