SHORT-TERM AND MIDTERM RESULTS OF BALLOON VALVULOPLASTY FOR VALVULAR AORTIC-STENOSIS IN CHILDREN

被引:44
|
作者
WITSENBURG, M
CROMMEDIJKHUIS, AH
FROHNMULDER, IME
HESS, J
机构
[1] Department of Pediatrics, Division of Pediatric Cardiology, Sophia Childrens' Hospital, Rotterdam
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1992年 / 69卷 / 09期
关键词
D O I
10.1016/0002-9149(92)90798-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During a 27-month period, 21 consecutive children (aged 0.1 to 15.7 years) with isolated valvular aortic stenosis underwent percutaneous transfemoral balloon valvuloplasty. Ten children had undergone earlier surgical valvulotomy. The indication for treatment was ST-T-segment changes at rest or during bicycle-ergometry, a continuous-wave Doppler-derived transvalvular gradient > 60 mm Hg or syncope, or a combination. Mean peak systolic left ventricular pressure decreased from 165 +/- 19 to 131 +/- 19 mm Hg (p < 0.001). Mean end-diastolic left ventricular pressure did not change significantly (12 +/- 3 vs 11 +/- 5 mm Hg). Mean peak systolic valve gradient decreased from 71 +/- 23 to 22 +/- 11 mm Hg (p < 0.001). Mean cardiac index remained unchanged (2.9 +/- 0.8 vs. 3.0 +/- 0.7 liters.min-1.m-2). Aortic valve regurgitation on angiography appeared or increased in 9 patients (up to grade 3 in 3 children). Noninvasive follow-up studies were performed for 2 to 4.2 years (mean 2.8). ST-T changes on the electrocardiogram at rest or during exercise were present in 6 patients before balloon valvuloplasty and had disappeared in all at 6-month follow-up. Reoccurrence of ST-T changes after a longer follow-up was associated with severe valve regurgitation. Syncope was not observed after balloon valvuloplasty. The continuous-wave Doppler gradient decreased from 94 +/- 36 to 49 +/- 15 mm Hg (p < 0.001). After a follow-up of 2 to 4.2 years (mean 2.8) it remained unchanged (43 +/- 13 mm Hg; p = not significant). Aortic regurgitation on echocardiography appeared or increased initially in 11 patients. In some patients after longer follow-up, an additional increase was observed. At the latest follow-up, grade 3 aortic regurgitation was present in 5 patients, 3 of whom underwent valve replacement. These 3 patients had undergone earlier surgical valvulotomy. Except for age, weight and left ventricular end-diastolic pressure before valvuloplasty, there were no differences between the earlier operated and nonoperated patients. Aortic valvuloplasty is effective and postpones surgery in the majority of patients. Occurence or increase of aortic valve regurgitation may be induced, leading to valve replacement in 14% of patients within 2 years.
引用
收藏
页码:945 / 950
页数:6
相关论文
共 50 条
  • [1] BALLOON VALVULOPLASTY FOR ISOLATED AORTIC-STENOSIS IN CHILDREN - SHORT-TERM RESULTS
    VOGEL, M
    BENSON, LN
    FREEDOM, RM
    ROWE, RD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A130 - A130
  • [2] CONGENITAL VALVULAR AORTIC-STENOSIS - RESULTS AFTER BALLOON VALVULOPLASTY
    RUPPRATH, G
    NEUHAUS, KL
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 14 - 14
  • [3] MEDIUM-TERM RESULTS OF PERCUTANEOUS BALLOON VALVULOPLASTY FOR THE TREATMENT OF VALVULAR AORTIC-STENOSIS IN CHILDHOOD AND ADOLESCENCE
    MARCON, F
    MICHALSKI, H
    WEBER, JL
    WORMS, AM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1993, 86 (05): : 563 - 569
  • [4] ANTEROGRADE BALLOON VALVULOPLASTY OF AORTIC-STENOSIS IN CHILDREN
    HAUSDORF, G
    SCHNEIDER, M
    SCHIRMER, KR
    SCHULZENEICK, I
    LANGE, PE
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (05): : 460 - 462
  • [5] BALLOON VALVULOPLASTY FOR AORTIC-STENOSIS
    HOLMES, DR
    HOSPITAL PRACTICE, 1990, 25 (01): : 69 - 77
  • [6] RESULTS OF BALLOON VALVULOPLASTY OF CONGENITAL VALVULAR AORTIC STENOSIS
    Zufarov, M. M.
    Iskandarov, F. A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S66 - S66
  • [7] FATAL AORTIC RUPTURE DURING PERCUTANEOUS BALLOON VALVULOPLASTY FOR VALVULAR AORTIC-STENOSIS
    LEMBO, NJ
    KING, SB
    ROUBIN, GS
    HAMMAMI, A
    NIEDERMAN, AL
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (08): : 733 - 736
  • [8] PERCUTANEOUS BALLOON VALVULOPLASTY FOR VALVAR AORTIC-STENOSIS IN CHILDREN
    WORMS, AM
    MARCON, F
    CLOEZ, JL
    PERNOT, C
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1988, 81 (05): : 617 - 625
  • [9] SHORT-TERM AND LONG-TERM SURVIVAL AFTER AORTIC BALLOON VALVULOPLASTY FOR CALCIFIED AORTIC-STENOSIS IN 137 ELDERLY PATIENTS
    KASTRUP, J
    WENNEVOLD, A
    THUESEN, L
    NIELSEN, TT
    KASSIS, E
    FRITZHANSEN, P
    THAYSSEN, P
    DANISH MEDICAL BULLETIN, 1994, 41 (03): : 362 - 365
  • [10] BALLOON VALVULOPLASTY FOR CALCIFIC AORTIC-STENOSIS
    MUNCEY, F
    SPRIGINGS, D
    THOMAS, S
    CHAMBERS, JB
    MONAGHAN, MJ
    JEWITT, D
    JACKSON, G
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 781 - 781