ASSAYS FOR RECOMBINANT PROTEINS - A PROBLEM IN NONLINEAR CALIBRATION

被引:20
作者
GILTINAN, DM [1 ]
DAVIDIAN, M [1 ]
机构
[1] N CAROLINA STATE UNIV,DEPT STAT,RALEIGH,NC 27695
关键词
D O I
10.1002/sim.4780131107
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantification of protein levels in biological matrices such as serum or plasma frequently relies on the techniques of immunoassay or bioassay. The relevant statistical problem is that of non-linear calibration, where one estimates analyte concentration in an unknown sample from a calibration curve fit to known standard concentrations. This paper discusses a general framework for calibration inference, that of the non-linear mixed effects model. Within this framework, we consider two issues in depth: accurate characterization of intra-assay variation, and the use of empirical Bayes methods in calibration. We show that proper characterization of intra-assay variability requires pooling of information across several assay runs. Simulation work indicates that use of empirical Bayes methods may afford considerable gain in efficiency; one must weigh this gain against practical considerations in the implementation of Bayesian techniques. We illustrate the methods discussed using a cell-based bioassay for the recombinant hormone relaxin.
引用
收藏
页码:1165 / 1179
页数:15
相关论文
共 20 条
[1]  
Carroll R., 1988, TRANSFORMATION WEIGH, DOI 10.1007/978-1-4899-2873-3
[2]   A COMPARISON BETWEEN MAXIMUM-LIKELIHOOD AND GENERALIZED LEAST-SQUARES IN A HETEROSCEDASTIC LINEAR-MODEL [J].
CARROLL, RJ ;
RUPPERT, D .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1982, 77 (380) :878-882
[3]   REGRESSION AND CALIBRATION WITH NONCONSTANT ERROR VARIANCE [J].
DAVIDIAN, M ;
HAALAND, PD .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1990, 9 (03) :231-248
[4]   SOME SIMPLE METHODS FOR ESTIMATING INTRAINDIVIDUAL VARIABILITY IN NONLINEAR MIXED EFFECTS MODELS [J].
DAVIDIAN, M ;
GILTINAN, DM .
BIOMETRICS, 1993, 49 (01) :59-73
[5]   VARIANCE FUNCTIONS AND THE MINIMUM DETECTABLE CONCENTRATION IN ASSAYS [J].
DAVIDIAN, M ;
CARROLL, RJ ;
SMITH, W .
BIOMETRIKA, 1988, 75 (03) :549-556
[6]  
Efron B., 1986, STAT SCI, P54, DOI DOI 10.1214/SS/1177013815
[7]  
Ekins RP, 1983, IMMUNOASSAYS CLIN CH
[8]   CYCLIC-AMP RESPONSE TO RECOMBINANT HUMAN RELAXIN BY CULTURED HUMAN ENDOMETRIAL CELLS - A SPECIFIC AND HIGH THROUGHPUT INVITRO BIOASSAY [J].
FEI, DTW ;
GROSS, MC ;
LOFGREN, JL ;
MORAWORMS, M ;
CHEN, AB .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1990, 170 (01) :214-222
[9]   RADIOLIGAND ASSAY [J].
FINNEY, DJ .
BIOMETRICS, 1976, 32 (04) :721-740
[10]   FITTING HETEROSCEDASTIC REGRESSION-MODELS TO INDIVIDUAL PHARMACOKINETIC DATA USING STANDARD STATISTICAL SOFTWARE [J].
GILTINAN, DM ;
RUPPERT, D .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1989, 17 (05) :601-614