VALIDATION PROCEDURES IN NEAR-INFRARED SPECTROMETRY

被引:26
|
作者
FORINA, M [1 ]
DRAVA, G [1 ]
BOGGIA, R [1 ]
LANTERI, S [1 ]
CONTI, P [1 ]
机构
[1] DIPARTIMENTO SCI CHIM,I-62032 CAMERINO,ITALY
关键词
INFRARED SPECTROMETRY; MOISTURE; MULTIVARIATE CALIBRATION; OIL; PARTIAL LEAST-SQUARES REGRESSION; PROTEINS; SOYA FLOUR; VALIDATION PROCEDURES;
D O I
10.1016/0003-2670(94)80340-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three validation procedures, single evaluation set, cross-validation and repeated evaluation set, were tested on near-infrared spectrometric data to evaluate the predictive residual standard deviation and the complexity of the regression model based on partial least-squares (PLS) regression. Thirty-six combinations of response variables and predictor variables (originating from three response variables and spectra recorded on the same 60 samples in four laboratories with different instruments) were tested. Each validation method was used with several different percentages of objects in the evaluation sets, from very low percentages (leave-one-out) to 33%. The results show that the frequently used technique of the single evaluation set gives a bad estimate both of the residual standard deviation and of the complexity of PLS model. Cross-validation gives acceptable estimates when at least ten cancellation groups are used. The validation technique based on the repeated evaluation set, with a large number of repetitions of prediction, gives excellent estimates of residual standard deviation and of model complexity, but it requires a very long computing time.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [1] Synthesis and near-infrared spectrometry
    Lodder, RA
    APPLIED SPECTROSCOPY, 1996, 50 (02) : A14 - &
  • [2] NEAR-INFRARED SPECTROMETRY OF WC STARS
    WILLIAMS, PM
    ADAMS, DJ
    ARAKAKI, S
    BEATTIE, DH
    BORN, J
    LEE, TJ
    ROBERTSON, DJ
    STEWART, JM
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1980, 192 (02) : P25 - P30
  • [3] NEAR-INFRARED SPECTROMETRY IN CLINICAL ANALYSIS
    不详
    ANALYTICAL CHEMISTRY, 1986, 58 (08) : A874 - +
  • [4] MOISTURE DETERMINATION BY NEAR-INFRARED SPECTROMETRY
    VORNHEDER, PF
    BRABBS, WJ
    ANALYTICAL CHEMISTRY, 1970, 42 (12) : 1454 - +
  • [5] OPTOACOUSTIC SPECTROMETRY IN NEAR-INFRARED REGION
    ADAMS, MJ
    BEADLE, BC
    KIRKBRIGHT, GF
    ANALYTICAL CHEMISTRY, 1978, 50 (09) : 1371 - 1374
  • [6] VALIDATION OF NEAR-INFRARED SPECTROSCOPY IN MAN
    MANCINI, DM
    FARRELL, L
    WILSON, JR
    CIRCULATION, 1992, 86 (04) : 401 - 401
  • [7] VALIDATION OF NEAR-INFRARED SPECTROSCOPY IN HUMANS
    MANCINI, DM
    BOLINGER, L
    LI, H
    KENDRICK, K
    CHANCE, B
    WILSON, JR
    JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (06) : 2740 - 2747
  • [8] INFRARED NEAR-INFRARED SPECTROMETRY AND CHEMOMETRY - MULTIVARIATE CALIBRATION
    MENARDO, C
    ANALUSIS, 1993, 21 (10) : M32 - M34
  • [9] Transfer of calibration in near-infrared reflectance spectrometry
    Dreassi, E
    Ceramelli, G
    Perruccio, PL
    Corti, P
    ANALYST, 1998, 123 (06) : 1259 - 1264
  • [10] Near-infrared spectrometry for the characterization of feed resources
    Bastianelli, Denis
    Bonnal, Laurent
    Barre, Philippe
    Nabeneza, Serge
    Salgado, Paulo
    Andueza, Donato
    INRA PRODUCTIONS ANIMALES, 2018, 31 (03): : 237 - 254