Elective use of intra-aortic balloon pumping during Whipple's procedure in a patient with ischaemic heart disease

被引:0
作者
Subramanayam, K. [1 ]
Babu, B. [2 ]
Bhat, R. [3 ]
Reddy, S. [2 ]
机构
[1] Apollo Hosp, Dept Anaesthesiol, Bangalore, Karnataka, India
[2] Apollo Hosp, Dept Cardiothorac Surg, Bangalore, Karnataka, India
[3] Apollo Hosp, Dept Surg Gastroenterol, Bangalore, Karnataka, India
关键词
intra-aortic balloon pumping (IABP); coronary artery disease; noncardiac; surgery; Whipple's resection;
D O I
10.1080/22201173.2013.10872897
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A 61-year-old man with diabetes who presented with carcinoma of the head of the pancreas was detected to have severe coronary artery disease. Coronary artery bypass grafting was advised. In view of the urgent nature of the abdominal surgery, resection of the malignancy was carried out prior to coronary revascularisation, after placement of an intra-aortic balloon pump (IABP) following induction of anaesthesia to prevent perioperative myocardial ischaemia. The use of an IABP in a noncardiac setting is not well established. Only 16 cases have been reported. To the best of our knowledge, this is the second documented case of the use of elective IABP during Whipple's procedure. (C) SASA
引用
收藏
页码:77 / 79
页数:3
相关论文
共 14 条
  • [1] Preoperative evaluation of patients with, or at risk of, coronary artery disease undergoing non-cardiac surgery
    Chassot, PG
    Delabays, A
    Spahn, DR
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (05) : 747 - 759
  • [2] Cooper Howard A, 2008, Acute Card Care, V10, P214, DOI 10.1080/17482940802483048
  • [3] ACC/AHA Guidelines for Coronary Artery Bypass Graft Surgery: Executive summary and recommendations - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (committee to revise the 1991 Guidelines for Coronary Artery Bypass Graft Surgery)
    Eagle, KA
    Guyton, RA
    Davidoff, R
    Ewy, GA
    Fonger, J
    Gardner, TJ
    Gott, JP
    Herrmann, HC
    Marlow, RA
    Nugent, W
    O'Connor, GT
    Orszulak, TA
    Rieselbach, RE
    Winters, WL
    Yusuf, S
    Gibbons, RJ
    Alpert, JS
    Eagle, KA
    Gardner, TJ
    Garson, A
    Gregoratos, G
    Russell, RO
    Ryan, TJ
    Smit, SC
    [J]. CIRCULATION, 1999, 100 (13) : 1464 - 1480
  • [4] ACC/AHA guideline update for perioperative cardiovascular evaluation for noncardiac surgery - Executive summary
    Eagle, KA
    Berger, PB
    Calkins, H
    Chaitman, BR
    Ewy, GA
    Fleischmann, KE
    Fleisher, LA
    Froehlich, JB
    Gusberg, RJ
    Leppo, JA
    Ryan, T
    Schlant, RC
    Winters, WL
    Gibbons, RJ
    Antman, EM
    Alpert, JS
    Faxon, DP
    Fuster, V
    Gregoratos, G
    Jacobs, AK
    Hiratzka, LF
    Russell, RO
    Smith, SC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) : 542 - 553
  • [5] The current practice of intra-aortic balloon counterpulsation: Results from the Benchmark Registry
    Ferguson, JJ
    Cohen, M
    Freedman, RJ
    Stone, GW
    Miller, MF
    Joseph, DL
    Ohman, EM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) : 1456 - 1462
  • [6] Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting
    Field, M. L.
    Rengarajan, A.
    Khan, O.
    Spyt, T.
    Richens, D.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2007, (01):
  • [7] Gombar S, 2007, INDIAN J ANAESTH, V51, P287
  • [8] Anesthetic management of high-risk cardiac patients undergoing noncardiac surgery under the support of intraaortic balloon pump
    Masaki, E
    Takinami, M
    Kurata, Y
    Kagaya, S
    Ahmed, A
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 1999, 11 (04) : 342 - 345
  • [9] Intra-alortic balloon pump in patients with ischaemic heart disease undergoing oesophagogastrectomy
    Millat, MH
    Cameron, EWJ
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2003, 172 (04) : 177 - 179
  • [10] Elective intra-aortic balloon counterpulsation during a high risk liver resection
    Oliver, J. C.
    Welsh, F. K. S.
    Bell, J.
    Bishop, A. J.
    Glover, J.
    Rees, M.
    [J]. ANAESTHESIA, 2008, 63 (12) : 1365 - 1368