Structural, seismic and geotechnical analysis of the Sant' Agostino church in L'aquila (Italy)

被引:15
|
作者
Cennamo, Claudia [1 ]
Di Fiore, Marco [2 ]
机构
[1] Seconda Univ Napoli, Aversa, Italy
[2] Politecn Torino, Turin, Italy
来源
REVISTA INGENIERIA DE CONSTRUCCION | 2013年 / 28卷 / 01期
关键词
Seismic vulnerability; damage; seismic risk; modality of intervention; seismic analysis;
D O I
10.4067/S0718-50732013000100001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Existing masonry buildings are often the result of constructions, changes and alterations that have developed over the centuries. Therefore, the adaptation and improvement of existing masonry buildings must be accompanied by an adequate level of knowledge of their history. The tragic consequences of the recent earthquakes, in Italy and abroad, have stimulated the belief that, sometimes, the cause of seismic damage might be just the wrong intervention of improvement or adaptation. In most cases, this is attributable to retrofit works which are carried out without any knowledge concerning the construction rules of the building. The case study presented here regards the seismic analysis of the Sant' Agostino Church in L'Aquila (seriously damaged by the earthquake occurred in April 2009), which takes into account the in-depth knowledge of the factory, respecting all three evaluation levels of seismic safety provided by the Italian seismic Guidelines for Cultural Heritage (Eurocode 8, 2003; NTC, 2008). In particular for LV1 (Evaluation Level 1), all the analyses requested to fill the annexes of the Directive of December 10th, 2007 were carried out, starting from Module A, which is the "identifier registry", passing through Module B, which concerns the study of "sensitivity factors", and ending with Module C, which considers the "morphology of the elements". From this examination, we concluded that the ground acceleration during the earthquake of April 6th, 2009 surpassed the acceleration value corresponding to the limit state of collapse. For LV2 (Evaluation Level 2), we especially focused on the verification of all macro-elements as a potential source of damage mechanisms. In particular, we found that these mechanisms concerned mostly the facade, the hall, the dome, the apse/presbytery, the roofing, the side chapels, the joints between horizontal and vertical alignment, and finally, the bell tower. Once we collected all data regarding the site, the geometry of construction, the characteristics of the materials, the structure, the soil, etc., we carried out a dynamic FEM modal analysis on the structure, valid for LV3 (Evaluation Level 3). Moreover, these dynamic tests are essential for the evaluation of seismic safety and they also present the clear advantage of being non-destructive. Finally, the analysis provided the most significant vibration modes and suggested the optimal structural interventions to remedy the existing damage and prevent the formation of these mechanisms under the action of future earthquakes.
引用
收藏
页码:7 / 20
页数:14
相关论文
共 11 条
  • [1] Seismic response analysis in the southern part of the historic centre of the City of L'Aquila (Italy)
    Ferraro, A.
    Grasso, S.
    Maugeri, M.
    Totani, F.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2016, 88 : 256 - 264
  • [2] Comparison of seismic analysis methods applied to a historical church struck by 2009 L'Aquila earthquake
    Endo, Yohei
    Pela, Luca
    Roca, Pere
    da Porto, Francesca
    Modena, Claudio
    BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (12) : 3749 - 3778
  • [3] Damage Assessment by Numerical Modeling of Sant'Agostino's Sanctuary in Offida During the Central Italy 2016-2017 Seismic Sequence
    Giordano, Ersilia
    Clementi, Francesco
    Nespeca, Andrea
    Lenci, Stefano
    FRONTIERS IN BUILT ENVIRONMENT, 2019, 4
  • [4] DAMAGE SCENARIO INDUCED IN THE CITY OF ROME BY THE L'AQUILA SEISMIC SEQUENCE OF APRIL 2009 (ITALY)
    Bozzano, Francesca
    Giacomi, Anna Chiara
    Martino, Salvatore
    di Roma, Comando Provinciale dei Vigili del Fuoco
    ITALIAN JOURNAL OF ENGINEERING GEOLOGY AND ENVIRONMENT, 2011, 11 (02): : 5 - 22
  • [5] Ambient vibration test and numerical investigation on the St. Giuliano church in Poggio Picenze (L’aquila, Italy)
    Gianmaria Di Lorenzo
    Antonio Formisano
    Lidija Krstevska
    Raffaele Landolfo
    Journal of Civil Structural Health Monitoring, 2019, 9 : 477 - 490
  • [6] Ambient vibration test and numerical investigation on the St. Giuliano church in Poggio Picenze (L'aquila, Italy)
    Di Lorenzo, Gianmaria
    Formisano, Antonio
    Krstevska, Lidija
    Landolfo, Raffaele
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2019, 9 (04) : 477 - 490
  • [7] Structural performance of the historic and modern buildings of the University of L'Aquila during the seismic events of April 2009
    Ceci, A. M.
    Contento, A.
    Fanale, L.
    Galeota, D.
    Gattulli, V.
    Lepidi, M.
    Potenza, F.
    ENGINEERING STRUCTURES, 2010, 32 (07) : 1899 - 1924
  • [8] Seismic risk analysis on masonry buildings damaged by L'Aquila 2009 and Emilia 2012 earthquakes
    Tatangelo, M.
    Audisio, L.
    D'Amato, M.
    Gigliotti, R.
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 990 - 997
  • [9] Temporal Evolution of Radiated Energy to Seismic Moment Scaling During the Preparatory Phase of the Mw 6.1, 2009 L'Aquila Earthquake (Italy)
    Picozzi, M.
    Spallarossa, D.
    Iaccarino, A. G.
    Bindi, D.
    GEOPHYSICAL RESEARCH LETTERS, 2022, 49 (08)
  • [10] SEISMIC RESPONSE ANALYSIS AND REHABILITATION PROJECT FOR A HISTORICAL MASONRY CONSTRUCTION, DEMAGED BY THE L'AQUILA EARTHQUAKE OF 06 APRIL 2009
    Di Mattia, Andrea
    STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS, VOLS 1-3, 2012, : 1465 - 1473