COMPARISON BETWEEN MAGIC LITE(R)-SYSTEM AND CAP(R)-SYSTEM - 2 AUTOMATED SPECIFIC IGE ANTIBODY-ASSAYS

被引:73
作者
KLEINETEBBE, J
EICKHOLT, M
GATJEN, M
BRUNNEE, T
OCONNOR, A
KUNKEL, G
机构
[1] FREE UNIV BERLIN,HOSP RUDOLF VIRCHOW,DEPT CLIN IMMUNOL,AUGUSTENBURGER PLATZ 1,W-1000 BERLIN 65,GERMANY
[2] FREE UNIV BERLIN,HOSP RUDOLF VIRCHOW,ASTHMA POLIKLIN,W-1000 BERLIN 65,GERMANY
关键词
D O I
10.1111/j.1365-2222.1992.tb00150.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The MAGIC LITE system, a newly developed immunochemiluminometric assay for specific and total IgE antibody using paramagnetic particles coupled with standardized allergens as solid phase, was compared to the CAP system, a recently introduced immunoassay based on a cellulose polymer encased in a capsule. A total of 357 serum samples of patients with suspected inhalant allergies and a positive skin prick test (SPT) to common allergens (birch, timothy-grass, mugwort, cat dander, Dermatophagoides pteronyssinus, Alternaria) were investigated. Fifty SPT negative subjects served as controls (total number of tests in each assay = 1600). Both assays were highly precise (overall intra-assay and inter-assay coefficients of variation were 2.9% and 4-5% in MAGIC LITE, 4.7% and 5.5% in CAP) and showed excellent linearity (mean r2 of eightfold log2 serum dilutions were 99.7% and 99.3% in MAGIC LITE and CAP). Good correlations were found between the absolute specific IgE antibody values detected by both methods (correlation coefficient r: birth 0.86, grass 0-93, mugwort 0.96, cat 0.91, D. pteronyssinus 0.73, Alternaria 0.90). Excellent specificity (greater-than-or-equal-to 98%) occurred in both assays and with all allergens, and sensitivity was related to the allergen (MAGIC LITE/CAP): birch 91%/89%, grass 83%/90%, mugwort 50%/69%, cat 83%/83%, D. pteronyssinus 72%/78%, Alternaria 75%/81%. Our results indicate that both in vitro tests are useful tools for the detection of specific IgE antibody.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 20 条
[1]  
AXEN R, 1988, P CLIN WORKSH IGE AN, P3
[2]   INVITRO DIAGNOSIS OF ATOPIC ALLERGY [J].
BERG, T ;
JOHANSSON, SGO .
INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1976, 51 (04) :471-481
[3]  
BERNSTEIN IL, 1988, J ALLERGY CLIN IM S3, V82, P499
[4]   COMPARISON BETWEEN RAST AND PHARMACIA CAP SYSTEM - A NEW AUTOMATED SPECIFIC IGE ASSAY [J].
BOUSQUET, J ;
CHANEZ, P ;
CHANAL, I ;
MICHEL, FB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 85 (06) :1039-1043
[5]  
BOUSQUET J, 1988, ALLERGY PRINCIPLES P, P419
[6]  
Ekins R., 1981, LIGAND Q, V4, P33
[7]   DIAGNOSIS OF REAGINIC ALLERGY WITH HOUSE DUST, ANIMAL DANDER AND POLLEN ALLERGENS IN ADULT PATIENTS .1. COMPARISON BETWEEN RAST, SKIN-TESTS AND PROVOCATION TESTS [J].
ERIKSSON, NE ;
AHLSTEDT, S ;
BELIN, L .
INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1976, 52 (1-4) :335-346
[8]   EVALUATION OF A CAPSULATED HYDROPHILIC CARRIER POLYMER (THE IMMUNOCAP) FOR MEASUREMENT OF SPECIFIC IGE ANTIBODIES [J].
EWAN, PW ;
COOTE, D .
ALLERGY, 1990, 45 (01) :22-29
[9]  
Galen R. S., 1975, NORMALITY PREDICTIVE
[10]  
HEINIG JG, 1990, 17TH P NORD C ALL AR, P156