FLUORESCENCE DECAY STUDIES APPLYING A CW FEMTOSECOND DYE-LASER PUMPED UNGATED INVERSE TIME-CORRELATED SINGLE PHOTON-COUNTING SYSTEM

被引:6
作者
BAUMLER, W
SCHMALZL, AX
GOSSL, G
PENZKOFER, A
机构
[1] Naturwissenschaftliche Fak. II-Phys., Regensburg Univ.
关键词
D O I
10.1088/0957-0233/3/4/009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An ungated inverse time-correlated single-photon counting system is described. The excitation source is a CW-pumped, linear prism-pair-stabilized, passive mode-locked femtosecond dye laser. The excitation pulse repetition rate is 120 MHz. The sample emission is detected with a microchannel plate photomultiplier tube. An iterative least-squares reconvolution method is applied to the data analysis. The fluorescence lifetimes, the reorientation times and the anisotropy factors of the dye solutions cresyl violet perchlorate and rhodamine 101 perchlorate in ethanol are determined.
引用
收藏
页码:384 / 393
页数:10
相关论文
共 51 条
[41]  
PENZKOFER A, 1991, OPT QUANT ELECTRON, V23, P685
[42]  
PENZKOFER A, 1991, OPT QUANT ELECTRON, V21, P727
[43]   A FAST DECONVOLUTION METHOD TO ANALYZE FLUORESCENCE DECAYS WHEN THE EXCITATION PULSE REPETITION PERIOD IS LESS THAN THE DECAY TIMES [J].
SAKAI, Y ;
HIRAYAMA, S .
JOURNAL OF LUMINESCENCE, 1988, 39 (03) :145-151
[44]   60-FSEC PULSE GENERATION FROM A SELF-MODE-LOCKED TI-SAPPHIRE LASER [J].
SPENCE, DE ;
KEAN, PN ;
SIBBETT, W .
OPTICS LETTERS, 1991, 16 (01) :42-44
[45]   SINGLE PHOTON TIMING SYSTEM FOR PICOSECOND FLUORESCENCE LIFETIME MEASUREMENTS [J].
TURKO, BT ;
NAIRN, JA ;
SAUER, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (01) :118-120
[46]   GENERATION OF OPTICAL PULSES AS SHORT AS 27 FEMTOSECONDS DIRECTLY FROM A LASER BALANCING SELF-PHASE MODULATION, GROUP-VELOCITY DISPERSION, SATURABLE ABSORPTION, AND SATURABLE GAIN [J].
VALDMANIS, JA ;
FORK, RL ;
GORDON, JP .
OPTICS LETTERS, 1985, 10 (03) :131-133
[47]   TUNABLE PASSIVE COLLIDING-PULSE MODE-LOCKING IN A LINEAR DYE-LASER [J].
VANHERZEELE, H ;
DIELS, JC ;
TORTI, R .
OPTICS LETTERS, 1984, 9 (12) :549-551
[48]   DOUBLE BEAM FLUORESCENCE LIFETIME SPECTROMETER WITH SUB-NANOSECOND RESOLUTION - APPLICATION TO AQUEOUS TRYPTOPHAN [J].
VANRESANDT, RWW ;
VOGEL, RH ;
PROVENCHER, SW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (09) :1392-1397
[49]   MEASUREMENT AND ANALYSIS OF FLUORESCENCE DECAY CURVES [J].
WILD, UP ;
HOLZWARTH, AR ;
GOOD, HP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (12) :1621-1627
[50]   A RAPID-SCANNING AUTO-CORRELATION SCHEME FOR CONTINUOUS MONITORING OF PICOSECOND LASER-PULSES [J].
YASA, ZA ;
AMER, NM .
OPTICS COMMUNICATIONS, 1981, 36 (05) :406-408