MINIMIZATION OF SENSITIVITY LOSSES DUE TO THE USE OF GRADIENT PULSES IN TRIPLE-RESONANCE NMR OF PROTEINS

被引:0
作者
STONEHOUSE, J
CLOWES, RT
SHAW, GL
KEELER, J
LAUE, ED
机构
[1] UNIV CAMBRIDGE,DEPT CHEM,CAMBRIDGE CB2 1EW,ENGLAND
[2] UNIV CAMBRIDGE,DEPT BIOCHEM,CAMBRIDGE CB2 1QW,ENGLAND
关键词
TRIPLE RESONANCE; PULSED FIELD GRADIENTS; COHERENCE SELECTION; SENSITIVITY; NH EXCHANGE;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The use of pulsed field gradients in multiple-pulse NMR experiments has many advantages, including the possibility of obtaining excellent water suppression without the need for selective presaturation. In such gradient experiments the water magnetization is dephased deliberately; exchange between the saturated protons of the solvent water and the NH protons of a protein transfers this saturation to the protein. As the solvent is in large excess and relaxes relatively slowly, the result is a reduction in the sensitivity of the experiment due to the fact that the NH proton magnetization is only partially recovered. These effects can be avoided by ensuring that the water magnetization remains intact and is returned to the +z-axis at the start of data acquisition. General procedures for achieving this aim in any triple-resonance experiment are outlined and two specific examples are given. Experimental results confirm the sensitivity advantage of the modified sequences.