DETERMINATION OF MERCURY IN REAL SAMPLES BY ATOMIC SPECTROMETRY AND STRIPPING VOLTAMMETRY

被引:0
作者
Popescu, Luisa-Roxana [1 ]
Ungureanu, Eleonora-Mihaela [1 ]
Buica, G. -O. [1 ]
Dinu, Cristina [2 ]
Iordache, Mihaela [3 ]
机构
[1] Univ Politehn Bucuresti, Dept Appl Phys Chem & Electrochem, Bucharest, Romania
[2] Natl Res & Dev Inst Ind Ecol Ramnicu Valcea Subsi, Bucharest, Romania
[3] Univ Politehn Bucuresti, Dept Appl Phys Chem & Electrochem, Natl Res & Dev Inst Ind Ecol Ramnicu Valcea Subsi, Bucharest, Romania
来源
UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE | 2013年 / 75卷 / 04期
关键词
atomic absorption spectrometry; mercury; modified electrodes; anodic stripping voltammetry;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The mercury detection from real samples of soil using chemically modified electrodes with films based on pyrrole-EDTA monomer was performed and the results were compared to those obtained by Atomic Absorption Apectroscopy, currently used in environmental laboratory analysis. The ligand used for electrode modification is ethylendiaminotetra-N-(3-pyrrole-1-yl)propylacetamide (L). The electrochemical method used for mercury detection was the anodic stripping voltammetry on polyL modified electrodes. The experiments have shown that mercury levels obtained by both methods are comparable.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 16 条
  • [1] A new Schiff's base ligand immobilized agarose membrane optical sensor for selective monitoring of mercury ion
    Alizadeh, Kamal
    Parooi, Razieh
    Hashemi, Payman
    Rezaei, Behrooz
    Ganjali, Mohammad Reza
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 186 (2-3) : 1794 - 1800
  • [2] [Anonymous], 1999, 114661999 SR ISO
  • [3] [Anonymous], 2007, 14832007 SR EN
  • [4] [Anonymous], 1985, STRIPPING ANAL PRINC
  • [5] Bhan Ashima, 2005, Reviews on Environmental Health, V20, P39
  • [6] Ecological effects, transport, and fate of mercury: a general review
    Boening, DW
    [J]. CHEMOSPHERE, 2000, 40 (12) : 1335 - 1351
  • [7] Buica GO, 2009, J OPTOELECTRON ADV M, V11, P1152
  • [8] Voltammetric Sensing of Mercury and Copper Cations at Poly(EDTA-like) Film Modified Electrode
    Buica, George O.
    Bucher, Christophe
    Moutet, Jean-Claude
    Royal, Guy
    Saint-Aman, Eric
    Ungureanu, Eleonora M.
    [J]. ELECTROANALYSIS, 2009, 21 (01) : 77 - 86
  • [9] Films of poly(4-azulen-1-yl-2,6-bis(2-thienyl)pyridine) for heavy metal ions complexation
    Buica, George-Octavian
    Ungureanu, Eleonora-Mihaela
    Birzan, Liviu
    Razus, Alexandru C.
    Bujduveanu, Magdalena-Rodica
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (14) : 5028 - 5036
  • [10] Ion-selective electrode potentiometry in environmental analysis
    De Marco, Roland
    Clarke, Graeme
    Pejcic, Bobby
    [J]. ELECTROANALYSIS, 2007, 19 (19-20) : 1987 - 2001