摘要
Magnetic resonance imaging (MRI) studies of the heart have been used for some years, but there are few tools available to quantify cardiac motion. A method has been developed that creates an M-mode MRI image, analogous to the one used in echocardiography, to display motion along a line as a function of time. The M-mode image is created from MRI images acquired with an ordinary gradient echo cine sequence. In a cinematographic display of the images, a cursor line can be positioned in order to determine the orientation of the measurement. A resampling algorithm then calculates the appearance of the M-mode image along the cursor line. The MRI method has been compared to echocardiographic M-mode in a phantom study and by measuring mitral and tricuspid annulus motion in 20 normal subjects. The phantom study showed no significant differences between MRI and echocardiographic M-mode measurements (difference < 1 mm). The annulus motion exhibits a similar pattern using both methods and the measured amplitudes are in close agreement. M-mode MRI provides similar information to echocardiography, but the cursor line can be placed arbitrarily within the image plane and the method is thus not limited to certain acoustic windows. This makes M-mode MRI a promising technique fdr assessing cardiac motion.
引用
收藏
页码:397 / 407
页数:11
相关论文
共 16 条
[1]  
Bracewell R.M., The Fourier Transform and its Applications., (1965)
[2]  
Burbank F., Parish D., Wexler L., Echocardiographic‐like angled views of the heart by MR imaging, J Comput Assist Tomogr, 12, pp. 181-195, (1988)
[3]  
Feigenbaum H., Echocardiography, pp. 90-95, (1994)
[4]  
Gardner M.J., Altman D.G., Confidence intervals rather than P‐values: estimation rather than hypothesis testing, Br Med J, 292, pp. 746-750, (1986)
[5]  
Hammarstrom E., Wranne B., Pinto F.J., Puryear J., Popp R.L., Tricuspid annular motion, J Am Soc Echocardiogr, 4, pp. 131-139, (1991)
[6]  
Hardy C.J., Pearlman J.D., Moore J.R., Roemer P.B., Cline E.C., Rapid NMR cardiography with half‐echo M‐mode method, J Comput Assist Tomogr, 15, pp. 868-874, (1991)
[7]  
Hardy C.J., Darrow R.D., Nieters E.J., Roemer P.B., Watkins R.D., Adams W.J., Hattes N.R., Maier J.K., Real‐time acquisition, display and interactive graphic control of NMR cardiac profiles and images, Magn Reson Med, 29, pp. 667-673, (1993)
[8]  
Kondo T., Kurokawa H., Anno H., Okamura M., Anno N., Sakakura K., Tokuda M., Hishida H., Watanabe Y., Mizuno Y., Sughiishi M., Evaluation of cardiac motion and function by cine magnetic resonance imaging, Jpn Circ J, 56, pp. 632-640, (1992)
[9]  
Lenz G.W., Haacke E.M., White R.D., Retrospective cardiac gating: a review of technical aspects and future directions, Magn Reson Imaging, 7, pp. 445-455, (1989)
[10]  
Maier S.E., Fischer S.E., Mckinnon G.C., Hess O.M., Krayenbuehl H.P., Boesiger P., Acquisition and evaluation of tagged magnetic resonance images of the human left ventricle, Comput Med Imaging Graph, 16, pp. 73-80, (1992)