AUTOMATIC LEFT-VENTRICULAR VOLUME MEASUREMENTS ON CONTRAST-ENHANCED ULTRAFAST CINE MAGNETIC-RESONANCE-IMAGING

被引:3
|
作者
MATSUMURA, K
NAKASE, E
HAIYAMA, T
UTSUNOMIYA, S
机构
[1] Department of Internal Medicine, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaninakano-cho, Nishishichijyo
[2] Department of Radiology, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaminakano-cho, Nishishichijyo
[3] Central Research Institute, Shimadzu Corporation, Nakagyo-ku, Kyoto, 604
关键词
MAGNETIC RESONANCE (MR) IMAGING; HEART; MAGNETIC RESONANCE (MR); TECHNIQUE; MRI;
D O I
10.1016/0720-048X(95)00641-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the accuracy of automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine magnetic resonance (MR) images, we compared the values obtained by this method with those obtained using intravenous digital subtraction left ventriculography. High-quality single breath-hold contrast-enhanced ultrafast cine MR images were obtained in all cardiac phases on horizontal and vertical long axis sections of the left ventricle. For ultrafast cine MR imaging, a phase-rewind gradient-echo (rewind-SMASH) sequence was used. Automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine MR images was performed in all cardiac phases. High-quality left ventricular images of the horizontal long axis section were obtained in 127 of 160 patients (79%). The automatic extraction of the left ventricular contour was easily performed on high-quality images with very short processing time (4 s/frame). The values for left ventricular volumes obtained with the automatic extraction method on contrast-enhanced ultrafast cine MR imaging were correlated well with those obtained with the manual extraction method and IV-DSA in high quality cardiac images. The biplane modified Simpson's method using automatic extraction is an accurate and highly reproducible method for evaluating left ventricular volumes.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 50 条
  • [21] Contrast-Enhanced Magnetic Resonance Imaging of Gastric Emptying and Motility in Rats
    Lu, Kun-Han
    Cao, Jiayue
    Oleson, Steven Thomas
    Powley, Terry L.
    Liu, Zhongming
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (11) : 2546 - 2554
  • [22] Dynamic contrast-enhanced magnetic resonance imaging for head and neck cancers
    Elhalawani, Hesham
    Ger, Rachel B.
    Mohamed, Abdallah S. R.
    Awan, Musaddiq J.
    Ding, Yao
    Li, Kimberly
    Fave, Xenia J.
    Beers, Andrew L.
    Driscoll, Brandon
    Hormuth, David A., II
    van Houdt, Petra J.
    He, Renjie
    Zhou, Shouhao
    Mathieu, Kelsey B.
    Li, Heng
    Coolens, Catherine
    Chung, Caroline
    Bankson, James A.
    Huang, Wei
    Wang, Jihong
    Sandulache, Vlad C.
    Lai, Stephen Y.
    Howell, Rebecca M.
    Stafford, R. Jason
    Yankeelov, Thomas E.
    van der Heide, Uulke A.
    Frank, Steven J.
    Barboriak, Daniel P.
    Hazle, John D.
    Court, Laurence E.
    Kalpathy-Cramer, Jayashree
    Fuller, Clifton D.
    SCIENTIFIC DATA, 2018, 5
  • [23] Automatic deep learning method for detection and classification of breast lesions in dynamic contrast-enhanced magnetic resonance imaging
    Gao, Weibo
    Chen, Jixin
    Zhang, Bin
    Wei, Xiaocheng
    Zhong, Jinman
    Li, Xiaohui
    He, Xiaowei
    Zhao, Fengjun
    Chen, Xin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2620 - +
  • [24] Tumor flood volume assays using contrast-enhanced magnetic resonance imaging: Regional heterogeneity and postmortem artifacts
    Okuhata, Y
    Brasch, RC
    Pham, CD
    Daldrup, H
    Wendland, MF
    Shames, DM
    Roberts, TPL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (05) : 685 - 690
  • [25] The effect of time delay for magnetic resonance contrast-enhanced scan on imaging for small-volume brain metastases
    Chen, Mingming
    Wang, Pengcheng
    Guo, Yujie
    Yin, Yong
    Wang, Lizhen
    Su, Ya
    Gong, Guanzhong
    NEUROIMAGE-CLINICAL, 2022, 36
  • [26] Clinical Evaluation of Left Ventricular Diastolic Function Using Phase-contrast Cine Cardiovascular Magnetic Resonance Imaging: A Comparison With Steady-state Free Precession Cine Cardiovascular Magnetic Resonance Imaging and Echocardiography
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Miyatake, Hiroki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 56 - 63
  • [27] SEMIQUANTITATIVE AND QUANTITATIVE DYNAMIC CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING MEASUREMENTS PREDICT RADIATION RESPONSE IN CERVIX CANCER
    Zahra, Mark A.
    Tan, Li Tee
    Priest, Andrew N.
    Graves, Martin J.
    Arends, Mark
    Crawford, Robin A. F.
    Brenton, James D.
    Lomas, David J.
    Sala, Evis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 766 - 773
  • [28] VALIDATION OF RIGHT-VENTRICULAR VOLUME MEASUREMENTS BY MAGNETIC-RESONANCE-IMAGING IN SMALL HEARTS USING A FETAL LAMB MODEL
    STAUFFER, NR
    GREENBERG, SB
    MARKS, LA
    SINGH, GK
    SIDERIO, DL
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 87 - 89
  • [29] Ultrafast Computation of Left Ventricular Ejection Fraction by Using Temporal Intensity Variation in Cine Cardiac Magnetic Resonance
    Pednekar, Amol S.
    Cheong, Benjamin Y. C.
    Muthupillai, Raja
    TEXAS HEART INSTITUTE JOURNAL, 2021, 48 (04)
  • [30] Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer
    Kim, Eun Young
    Youn, Inyoung
    Lee, Kwan Ho
    Yun, Ji-Sup
    Park, Yong Lai
    Park, Chan Heun
    Moon, Juhee
    Choi, Seon Hyeong
    Choi, Yoon Jung
    Ham, Soo-Youn
    Kook, Shin Ho
    JOURNAL OF BREAST CANCER, 2018, 21 (04) : 453 - 462