AUTOMATIC LEFT-VENTRICULAR VOLUME MEASUREMENTS ON CONTRAST-ENHANCED ULTRAFAST CINE MAGNETIC-RESONANCE-IMAGING

被引:3
|
作者
MATSUMURA, K
NAKASE, E
HAIYAMA, T
UTSUNOMIYA, S
机构
[1] Department of Internal Medicine, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaninakano-cho, Nishishichijyo
[2] Department of Radiology, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaminakano-cho, Nishishichijyo
[3] Central Research Institute, Shimadzu Corporation, Nakagyo-ku, Kyoto, 604
关键词
MAGNETIC RESONANCE (MR) IMAGING; HEART; MAGNETIC RESONANCE (MR); TECHNIQUE; MRI;
D O I
10.1016/0720-048X(95)00641-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the accuracy of automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine magnetic resonance (MR) images, we compared the values obtained by this method with those obtained using intravenous digital subtraction left ventriculography. High-quality single breath-hold contrast-enhanced ultrafast cine MR images were obtained in all cardiac phases on horizontal and vertical long axis sections of the left ventricle. For ultrafast cine MR imaging, a phase-rewind gradient-echo (rewind-SMASH) sequence was used. Automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine MR images was performed in all cardiac phases. High-quality left ventricular images of the horizontal long axis section were obtained in 127 of 160 patients (79%). The automatic extraction of the left ventricular contour was easily performed on high-quality images with very short processing time (4 s/frame). The values for left ventricular volumes obtained with the automatic extraction method on contrast-enhanced ultrafast cine MR imaging were correlated well with those obtained with the manual extraction method and IV-DSA in high quality cardiac images. The biplane modified Simpson's method using automatic extraction is an accurate and highly reproducible method for evaluating left ventricular volumes.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 50 条
  • [1] The potential of contrast-enhanced magnetic resonance imaging for predicting left ventricular remodeling
    Watzinger, N
    Lund, GK
    Higgins, CB
    Wendland, MF
    Weinmann, HJ
    Saeed, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (06) : 633 - 640
  • [2] QUANTIFICATION OF TISSUE-PLASMA VOLUME IN THE RAT BY CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING
    KUWATSURU, R
    SHAMES, DM
    MUHLER, A
    MINTOROVITCH, J
    VEXLER, V
    MANN, JS
    COHN, F
    PRICE, D
    HUBERTY, J
    BRASCH, RC
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 76 - 81
  • [3] LEFT-VENTRICULAR ANEURYSMECTOMY AFTER MYOCARDIAL-INFARCTION FOLLOWING DETECTION OF LEFT-VENTRICULAR THROMBOSIS BY MAGNETIC-RESONANCE-IMAGING
    LALISANG, RR
    BAUR, LHB
    VANDERWALL, EE
    DEROOS, A
    BRUSCHKE, AVG
    MAGNETIC RESONANCE IMAGING, 1990, 8 (05) : 661 - 663
  • [4] MEASUREMENT OF REGIONAL LEFT-VENTRICULAR FUNCTION USING LABELED MAGNETIC-RESONANCE-IMAGING
    BUCHALTER, MB
    SIMS, C
    DIXON, AK
    WEISSBERG, PL
    STONE, DL
    SHAH, NJ
    HALL, LD
    WILKINSON, ID
    LOMAS, DJ
    FREER, CEL
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766) : 953 - 958
  • [5] Left-ventricular reduction surgery: Pre- and postoperative evaluation by cine magnetic resonance imaging
    Kivelitz, DE
    Hotz, H
    Borges, AC
    Enzweiler, CNH
    Wiese, TH
    Lembcke, A
    Konertz, W
    Baumann, G
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 336 - 340
  • [6] NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING
    SEMELKA, RC
    TOMEI, E
    WAGNER, S
    MAYO, J
    KONDO, C
    SUZUKI, J
    CAPUTO, GR
    HIGGINS, CB
    RADIOLOGY, 1990, 174 (03) : 763 - 768
  • [7] Advances in Contrast Agents for Contrast-Enhanced Magnetic Resonance Imaging
    Khairnar, Snehal
    More, Namdev
    Mounika, Choppadandi
    Kapusetti, Govinda
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (04) : 575 - 589
  • [8] EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING
    SAKUMA, H
    FUJITA, N
    FOO, TKF
    CAPUTO, GR
    NELSON, SJ
    HARTIALA, J
    SHIMAKAWA, A
    HIGGINS, CB
    RADIOLOGY, 1993, 188 (02) : 377 - 380
  • [9] Sensitive physiologic imaging with contrast-enhanced magnetic resonance imaging
    Litt, L
    ANESTHESIOLOGY, 1998, 88 (04) : 847 - 850
  • [10] Vascularity and Dynamic Contrast-Enhanced Breast Magnetic Resonance Imaging
    Frankhouser, David E.
    Dietze, Eric
    Mahabal, Ashish
    Seewaldt, Victoria L.
    FRONTIERS IN RADIOLOGY, 2021, 1