NEUTRON-ACTIVATION ANALYSIS FOR REFERENCE DETERMINATION OF THE IMPLANTATION DOSE OF COBALT IONS

被引:7
|
作者
GARTEN, RPH
BUBERT, H
PALMETSHOFER, L
机构
[1] INST SPEKTROCHEM & ANGEW SPEKT,W-4600 DORTMUND 1,GERMANY
[2] JOHANNES KEPLER UNIV,INST EXPTL PHYS,A-4040 LINZ,AUSTRIA
关键词
D O I
10.1021/ac00034a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reliable quantification of methods for surface and depth profiling analysis depends on the availability of reference materials for calibration. Since precision of depth profiling analysis procedures reaches the 1-2% level, the elemental contents In reference materials should be characterized with according accuracy. As an example, we prepared depth profiling reference materials by cobalt ion implantation at an ion energy Of 300 keV into n-type silicon; the implanted Co dose was monitored by ion current measurement (ICM). The total implanted Co ion doses were determined by instrumental neutron activation analysis (NAA) in the standard comparison mode, within a dynamic range of nearly 5 decades. The uncertainty amounted to less than 1.5%. It was found that the relative blas was (10 +/- 3) % of the implantation dose as measured by ICM in the dose range from 10(12) to 10(17) Co ions/cm2. Sources of error (beam spreading, misalignment) can be corrected for in this way. The advantages of this approach with similar samples of this type is outlined. The detection limit was 5 x 10(9) Co ions/cm2. It can be improved to lower than 10(9) ions/cm2 for 27 elements to be implanted in high-purity materials.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 50 条
  • [41] SUBSTOICHIOMETRIC DETERMINATION OF COPPER BY NEUTRON-ACTIVATION ANALYSIS
    AMLANI, AM
    TUREL, ZR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1990, 144 (01): : 27 - 33
  • [42] DETERMINATION OF IRON ISOTOPES BY NEUTRON-ACTIVATION ANALYSIS
    BURGIO, N
    CAPANNESI, G
    CIAVOLA, C
    SEDDA, AF
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1995, 201 (03): : 225 - 231
  • [43] NONDESTRUCTIVE AND DESTRUCTIVE DETERMINATION OF COBALT IN NICKEL-BASE ALLOYS BY NEUTRON-ACTIVATION ANALYSIS
    TAMURA, N
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1976, 278 (04): : 283 - 284
  • [44] SUBSTOICHIOMETRIC DETERMINATION OF MANGANESE BY NEUTRON-ACTIVATION ANALYSIS
    ZEMAN, A
    PRASILOVA, J
    RUZICKA, J
    TALANTA, 1966, 13 (03) : 457 - +
  • [45] DETERMINATION OF SILVER IN ROCKS BY NEUTRON-ACTIVATION ANALYSIS
    NADKARNI, RA
    MORRISON, GH
    ANALYTICAL CHEMISTRY, 1975, 47 (13) : 2285 - 2286
  • [46] DETERMINATION OF GUNSHOT RESIDUES BY NEUTRON-ACTIVATION ANALYSIS
    MENKE, H
    LESZCZYN.C
    WEBER, M
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 15 (01): : 27 - 32
  • [47] THE DETERMINATION OF SAMPLING CONSTANTS BY NEUTRON-ACTIVATION ANALYSIS
    HEYDORN, K
    DAMSGAARD, E
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 110 (02): : 539 - 553
  • [48] NIMROC SAMPLES AS REFERENCE MATERIALS FOR NEUTRON-ACTIVATION ANALYSIS
    ERASMUS, CS
    FESQ, HW
    KABLE, EJD
    RASMUSSEN, SE
    SELLSCHOP, JPF
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 39 (1-2): : 323 - 334
  • [49] DETERMINATION OF ARSENIC, MERCURY AND SELENIUM IN BIOLOGICAL STANDARD REFERENCE MATERIALS BY NEUTRON-ACTIVATION ANALYSIS
    BANDO, S
    IMAHASHI, T
    BUNSEKI KAGAKU, 1977, 26 (02) : 138 - 141
  • [50] A METHOD OF CHECKING REFERENCE SPECIMENS FOR NEUTRON-ACTIVATION ANALYSIS
    PUSHKIN, SG
    MIKHAILOV, VA
    GILBERT, EN
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1984, 39 (04): : 605 - 607