NEUTRON-ACTIVATION ANALYSIS FOR REFERENCE DETERMINATION OF THE IMPLANTATION DOSE OF COBALT IONS

被引:7
|
作者
GARTEN, RPH
BUBERT, H
PALMETSHOFER, L
机构
[1] INST SPEKTROCHEM & ANGEW SPEKT,W-4600 DORTMUND 1,GERMANY
[2] JOHANNES KEPLER UNIV,INST EXPTL PHYS,A-4040 LINZ,AUSTRIA
关键词
D O I
10.1021/ac00034a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reliable quantification of methods for surface and depth profiling analysis depends on the availability of reference materials for calibration. Since precision of depth profiling analysis procedures reaches the 1-2% level, the elemental contents In reference materials should be characterized with according accuracy. As an example, we prepared depth profiling reference materials by cobalt ion implantation at an ion energy Of 300 keV into n-type silicon; the implanted Co dose was monitored by ion current measurement (ICM). The total implanted Co ion doses were determined by instrumental neutron activation analysis (NAA) in the standard comparison mode, within a dynamic range of nearly 5 decades. The uncertainty amounted to less than 1.5%. It was found that the relative blas was (10 +/- 3) % of the implantation dose as measured by ICM in the dose range from 10(12) to 10(17) Co ions/cm2. Sources of error (beam spreading, misalignment) can be corrected for in this way. The advantages of this approach with similar samples of this type is outlined. The detection limit was 5 x 10(9) Co ions/cm2. It can be improved to lower than 10(9) ions/cm2 for 27 elements to be implanted in high-purity materials.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 50 条
  • [21] SUBSTOICHIOMETRIC DETERMINATION OF SILVER BY NEUTRON-ACTIVATION ANALYSIS
    MENDES, IA
    TUREL, ZR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1986, 106 (05): : 273 - 279
  • [22] DETERMINATION OF MERCURY IN BISMUTH BY NEUTRON-ACTIVATION ANALYSIS
    HIROSE, A
    HORIUCHI, I
    ISHII, D
    ANALYTICA CHIMICA ACTA, 1975, 75 (01) : 41 - 46
  • [23] DETERMINATION OF CADMIUM IN ROCKS BY NEUTRON-ACTIVATION ANALYSIS
    BILEFIELD, L
    VINCENT, EA
    ANALYST, 1961, 86 (102) : 386 - &
  • [24] SUBSTOICHIOMETRIC DETERMINATION OF MERCURY BY NEUTRON-ACTIVATION ANALYSIS
    NADKARNI, RA
    HALDAR, BC
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1972, 10 (02): : 181 - &
  • [25] DETERMINATION OF CADMIUM IN PETROLEUM BY NEUTRON-ACTIVATION ANALYSIS
    FILBY, RH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, (AUG26): : 23 - 23
  • [26] VARIATIONS ON THE DETERMINATION OF PHOSPHORUS BY NEUTRON-ACTIVATION ANALYSIS
    KLEPPINGER, EW
    YATES, SW
    JOURNAL OF CHEMICAL EDUCATION, 1986, 63 (11) : 987 - 987
  • [27] SUBSTOICHIOMETRIC DETERMINATION OF CD BY NEUTRON-ACTIVATION ANALYSIS
    SUBRAMANIAN, S
    TUREL, ZR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1987, 118 (03): : 193 - 199
  • [28] DETERMINATION OF LITHIUM BY INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS
    HEYDORN, K
    SKANBORG, PZ
    GWOZDZ, R
    SCHMIDT, JO
    WACKS, ME
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 37 (01): : 155 - 168
  • [29] SUBSTOICHIOMETRIC DETERMINATION OF CHROMIUM BY NEUTRON-ACTIVATION ANALYSIS
    KUDO, K
    SHIGEMATSU, T
    KOBAYASHI, K
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 36 (01): : 65 - 75
  • [30] APPLICATION OF NEUTRON-ACTIVATION ANALYSIS FOR DETERMINATION OF IMPLANTATION PROFILES OF PHOSPHORUS IN SEMICONDUCTOR GRADE SILICON
    JASKOLSKA, H
    ROWINSKA, L
    WALIS, L
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 38 (1-2): : 29 - 35