BENDING PROPERTIES OF WIRE-REINFORCED BONE-CEMENT FOR APPLICATIONS IN SPINAL FIXATION

被引:18
作者
SAHA, S
KRAAY, MJ
机构
[1] Biomechanics Laboratory, LSU Medical Center, Shreveport, Louisiana
[2] The University of Michigan, Ann Arbor, Michigan
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1979年 / 13卷 / 03期
关键词
Compendex;
D O I
10.1002/jbm.820130309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PMMA beam specimens were tested in four‐point bending to determine if the bending strength of acrylic bone cement, as used in posterior spinal fusion, could be improved by metal‐wire reinforcement. The result showed that the load‐carrying capacities of 1‐ and 0.5‐mm diam stainless‐steel‐wire‐reinforced PMMA specimens in bending were significantly higher than similar unreinforced normal PMMA samples. On an average, steel reinforcement comprising approximately 1% of the cross‐sectional area of the PMMA specimens caused a 15% increase in bending strength. Even after the cement fractured, the reinforcing wires still sustained an appreciable amount of bending moment, thus preventing catastrophic failure of cement alone. Copyright © 1979 John Wiley & Sons, Inc.
引用
收藏
页码:443 / 457
页数:15
相关论文
共 10 条
[1]  
Bresler B., 1974, REINFORCED CONCRETE, VI
[2]  
BRESLER B, REINFORCED CONCRETE, V2
[3]  
CHARNLEY J, 1970, ACRYLIC CEMENT ORTHO, P93
[4]  
DUNN E J, 1977, Spine, V2, P15, DOI 10.1097/00007632-197703000-00002
[5]   MODULUS OF ELASTICITY AND FLEXURAL STRENGTH OF SOME ACRYLIC BONE CEMENTS [J].
HOLM, NJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (05) :436-442
[6]   GRAPHITE FIBER REINFORCED BONE CEMENT - EXPERIMENTAL FEASIBILITY INVESTIGATION [J].
KNOELL, A ;
MAXWELL, H ;
BECHTOL, C .
ANNALS OF BIOMEDICAL ENGINEERING, 1975, 3 (02) :225-229
[7]  
SAHA S, 1978, 24TH ANN M T ORTH RE, V3, P299
[8]   USE OF ACRYLIC PLASTIC FOR VERTEBRAL REPLACEMENT OF FIXATION IN METASTATIC DISEASE OF SPINE [J].
SCOVILLE, WB ;
PALMER, AH ;
SAMRA, K ;
CHONG, G .
JOURNAL OF NEUROSURGERY, 1967, 27 (03) :274-&
[9]   TENSILE-STRENGTH OF WIRE-REINFORCED BONE CEMENT AND TWISTED STAINLESS-STEEL WIRE [J].
TAITSMAN, JP ;
SAHA, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (03) :419-425
[10]  
TIMOSHENKO SP, 1972, MECHANICS MATERIALS