Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference

被引:51
|
作者
Gao, Mingwu [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120 Engn Bldg, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
来源
PHYSIOLOGICAL REPORTS | 2016年 / 4卷 / 10期
关键词
Cuff-less blood pressure; PPG; pulse arrival time; pulse transit time; pulse wave velocity;
D O I
10.14814/phy2.12768
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I-PTT]) tightly correlates with BP. PTT estimated as the time delay between non-invasive proximal and distal arterial waveforms could therefore permit cuff-less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG-PTT). PAT and PPG-PTT were assessed as markers of BP over a wide physiologic range using I-PTT as a reference. Waveforms for determining I-PTT, PAT, and PPG-PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean +/- SE) standard deviation between 25 +/- 2 and 36 +/- 2 mmHg). I-PTT correlated well with all BP levels (group average R-2 values between 0.86 +/- 0.03 and 0.91 +/- 0.03). PPG-PTT also correlated well with all BP levels (group average R-2 values between 0.81 +/- 0.03 and 0.85 +/- 0.02), and its R-2 values were not significantly different from those of I-PTT. PAT correlated best with systolic BP (group average R-2 value of 0.70 +/- 0.04), but its R-2 values for all BP levels were significantly lower than those of I-PTT (P < 0.005) and PPG-PTT (P < 0.02). The pre-ejection period component of PAT was responsible for its inferior correlation with BP. In sum, PPG-PTT was not different from I-PTT and superior to the popular PAT as a marker of BP.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [2] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [3] Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models
    Barvik, Daniel
    Cerny, Martin
    Penhaker, Marek
    Noury, Norbert
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2022, 15 : 138 - 151
  • [4] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +
  • [5] Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure
    Zhang, Guanqun
    Gao, Mingwu
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) : 1681 - 1686
  • [6] Validation of continuous blood pressure measurements by pulse transit time: a comparison with invasive measurements in a cardiac intensive care unit
    Bartsch, S.
    Ostojic, D.
    Schmalgemeier, H.
    Bitter, T.
    Westerheide, N.
    Eckert, S.
    Horstkotte, D.
    Oldenburg, O.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2010, 135 (48) : 2406 - 2412
  • [7] Optimizing Non-Invasive Blood Pressure Estimation Using Pulse Transit Time
    Jeong, In Cheol
    Finkelstein, Joseph
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1198 - 1198
  • [8] Estimation of pulse transit time using two diametric blood pressure waveform measurements
    Hahn, Jin-Oh
    Reisner, Andrew T.
    Asada, H. Harry
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) : 753 - 759
  • [9] Assessment of Pulse Transit/Arrival Time as Noninvasive Blood Pressure Predictors in Finger and Earlobe Sites
    Selvaraj, Nandakumar
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 200 - 203
  • [10] Prototype of Wearable Device for Blood Pressure using Pulse Transit Time
    Bunkum, Manao
    Wanluk, Nutthanan
    Visitsattapongse, Sarinporn
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,