Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference

被引:53
作者
Gao, Mingwu [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120 Engn Bldg, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
关键词
Cuff-less blood pressure; PPG; pulse arrival time; pulse transit time; pulse wave velocity;
D O I
10.14814/phy2.12768
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I-PTT]) tightly correlates with BP. PTT estimated as the time delay between non-invasive proximal and distal arterial waveforms could therefore permit cuff-less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG-PTT). PAT and PPG-PTT were assessed as markers of BP over a wide physiologic range using I-PTT as a reference. Waveforms for determining I-PTT, PAT, and PPG-PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean +/- SE) standard deviation between 25 +/- 2 and 36 +/- 2 mmHg). I-PTT correlated well with all BP levels (group average R-2 values between 0.86 +/- 0.03 and 0.91 +/- 0.03). PPG-PTT also correlated well with all BP levels (group average R-2 values between 0.81 +/- 0.03 and 0.85 +/- 0.02), and its R-2 values were not significantly different from those of I-PTT. PAT correlated best with systolic BP (group average R-2 value of 0.70 +/- 0.04), but its R-2 values for all BP levels were significantly lower than those of I-PTT (P < 0.005) and PPG-PTT (P < 0.02). The pre-ejection period component of PAT was responsible for its inferior correlation with BP. In sum, PPG-PTT was not different from I-PTT and superior to the popular PAT as a marker of BP.
引用
收藏
页数:7
相关论文
共 14 条
[1]   DYNAMIC ELASTIC PROPERTIES OF ARTERIAL WALL [J].
BERGEL, DH .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03) :458-&
[2]   Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity [J].
Chen, Yan ;
Wen, Changyun ;
Tao, Guocai ;
Bi, Min ;
Li, Guoqi .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (11) :2222-2233
[3]   DETERMINATION OF PULSE-WAVE VELOCITIES WITH COMPUTERIZED ALGORITHMS [J].
CHIU, YC ;
ARAND, PW ;
SHROFF, SG ;
FELDMAN, T ;
CARROLL, JD .
AMERICAN HEART JOURNAL, 1991, 121 (05) :1460-1470
[4]   Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia [J].
Convertino, Victor A. ;
Cooke, William H. ;
Holcomb, John B. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (03) :629-634
[5]  
Cox H., 1978, AM J PHYSIOL, V234, P542
[6]   Improved Pulse Wave Velocity Estimation Using an Arterial Tube-Load Model [J].
Gao, Mingwu ;
Zhang, Guanqun ;
Olivier, N. Bari ;
Mukkamala, Ramakrishna .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) :848-858
[7]   PULSE ARRIVAL TIME AS A METHOD OF OBTAINING SYSTOLIC AND DIASTOLIC BLOOD-PRESSURE INDIRECTLY [J].
GEDDES, LA ;
VOELZ, M ;
JAMES, S ;
REINER, D .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) :671-672
[8]   ALTERATIONS WITH AGE IN VISCOELASTIC PROPERTIES OF HUMAN ARTERIAL WALLS [J].
LEAROYD, BM ;
TAYLOR, MG .
CIRCULATION RESEARCH, 1966, 18 (03) :278-+
[9]  
Milnor W. R., 1982, HEMODYNAMICS
[10]   Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice [J].
Mukkamala, Ramakrishna ;
Hahn, Jin-Oh ;
Inan, Omer T. ;
Mestha, Lalit K. ;
Kim, Chang-Sei ;
Toreyin, Hakan ;
Kyal, Survi .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) :1879-1901