EVALUATION OF ORAL CONTRAST AGENTS FOR ABDOMINAL MAGNETIC-RESONANCE-IMAGING

被引:11
作者
KRAUS, BB
RAPPAPORT, DC
ROS, PR
TORRES, GM
机构
[1] Department of Radiology, University of Florida, Gainesville, FL 32610
[2] The Toronto Hospital, Toronto, Ont. M5T 2S8
关键词
BARIUM; ORAL CONTRAST; MAGNETIC RESONANCE IMAGING;
D O I
10.1016/0730-725X(94)92025-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated the efficacy of sis available oral contrast agents in improving visualization of bou el and surrounding structures on magnetic resonance imaging of the abdomen and pelvis. Five volunteers were examined without oral contrast (baseline) and, on separate occasions, after ingestion of 600-900 cc of two positive contrasts [12.5% weight-to-volume (w/v) corn oil emulsion (COE), Redi Cat (EZ-Em Corp., Westbury, NY) mixed with 1% ferric ammonium citrate (FAC)] and four negative contrasts [220%, 105%, 85%, 60% w/v barium sulfate (Liquid HD, Liquid Polybar Plus, HD 85, reconstituted EZ Fake; EZ-Em Corp., Westbury, NY)]. Spin-echo axial and coronal T-1-weighted and axial T-2-weighted images were obtained in the abdomen and pelvis. Three radiologists blindly graded the images for improved visualization of bowel and surrounding structures, Data were analyzed for statistical significance using the General Linear Models algorithm. In the upper abdomen (stomach, duodenum, liver, and pancreas), COE yielded the highest mean scores (p <.0001), followed by 220% w/v barium. For the lower abdomen (ileum, colon), 220% w/v barium yielded the highest scores(p <.0001) and COE was much worse. The higher density barium preparations (220% and 105% w/v) yielded higher scores than their lower density counterparts (85% and 60%). All contrasts improved visualization of the retroperitoneum and spleen, but no one agent was best. All agents tested are superior to no agent at all. For visualization of the upper abdomen, 12.5% COE performed best. For visualization of the lower abdomen, 220% w/v barium performed best. For concurrent evaluation of both areas with one agent, 220% w/v barium performed best.
引用
收藏
页码:847 / 858
页数:12
相关论文
共 50 条
[21]   Inulin as a carrier for contrast agents in magnetic resonance imaging [J].
Corsi, DM ;
Vander Elst, L ;
Muller, RN ;
van Bekkum, H ;
Peters, JA .
CHEMISTRY-A EUROPEAN JOURNAL, 2001, 7 (01) :64-71
[22]   MAGNETIC-RESONANCE-IMAGING EVALUATION OF SPONTANEOUS PORTOSYSTEMIC COLLATERALS [J].
RAFAL, RB ;
KOSOVSKY, PA ;
JENNIS, R ;
MARKISZ, JA .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1990, 13 (01) :40-43
[23]   CARDIOVASCULAR MAGNETIC-RESONANCE-IMAGING - EVALUATION OF MYOCARDIAL PERFUSION [J].
ANDERSON, CM ;
BROWN, JJ .
CORONARY ARTERY DISEASE, 1993, 4 (04) :354-360
[24]   MAGNETIC-RESONANCE-IMAGING IN THE EVALUATION OF THE PORTAL VENOUS SYSTEM [J].
TAYLOR, CR ;
MCCAULEY, TR .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 1992, 14 (03) :268-273
[25]   MAGNETIC-RESONANCE-IMAGING IN THE PREOPERATIVE EVALUATION OF CERVICAL RADICULOPATHY [J].
WILSON, DW ;
PEZZUTI, RT ;
PLACE, JN .
NEUROSURGERY, 1991, 28 (02) :175-179
[26]   EFFICACY OF GADOTERIDOL FOR CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING IN CHILDREN [J].
BALL, WS ;
PARKER, JR ;
DAVIS, PC ;
GLASIER, CM ;
MORRIS, MR .
INVESTIGATIVE RADIOLOGY, 1992, 27 :S45-S52
[27]   CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF SUBDURAL AND EPIDURAL EMPYEMAS [J].
TSUCHIYA, K ;
MAKITA, K ;
FURUI, S ;
KUSANO, S ;
INOUE, Y .
NEURORADIOLOGY, 1992, 34 (06) :494-496
[28]   PRECLINICAL EVALUATION OF GADOLINIUM(III) TEXAPHYRIN COMPLEX - A NEW PARAMAGNETIC CONTRAST AGENT FOR MAGNETIC-RESONANCE-IMAGING [J].
YOUNG, SW ;
SIDHU, MK ;
QING, F ;
MULLER, HH ;
NEUDER, M ;
ZANASSI, G ;
MODY, TD ;
HEMMI, G ;
DOW, W ;
MUTCH, JD ;
SESSLER, JL ;
MILLER, RA .
INVESTIGATIVE RADIOLOGY, 1994, 29 (03) :330-338
[29]   MAGNETIC-RESONANCE-IMAGING OF THE HEART FOR SIZE EVALUATION OF ACUTE MYOCARDIAL-INFARCTION WITH AND WITHOUT CONTRAST AGENT [J].
GROTZ, J ;
KONERMANN, M ;
SORGE, B ;
BLUEMM, R ;
BEYER, HK .
HERZ KREISLAUF, 1991, 23 (04) :103-107
[30]   INVIVO AND INVITRO EVALUATION OF GD-DTPA-POLYLYSINE AS A MACROMOLECULAR CONTRAST AGENT FOR MAGNETIC-RESONANCE-IMAGING [J].
SCHUHMANNGIAMPIERI, G ;
SCHMITTWILLICH, H ;
FRENZEL, T ;
PRESS, WR ;
WEINMANN, HJ .
INVESTIGATIVE RADIOLOGY, 1991, 26 (11) :969-974