ISOTOPE-DILUTION GLOW-DISCHARGE MASS-SPECTROMETRY AS APPLIED TO THE ANALYSIS OF LEAD IN WASTE OIL SAMPLES

被引:9
|
作者
BARSHICK, CM [1 ]
SMITH, DH [1 ]
WADE, JW [1 ]
BAYNE, CK [1 ]
机构
[1] OAK RIDGE NATL LAB,DIV COMP & TELECOMMUN,OAK RIDGE,TN 37831
关键词
GLOW DISCHARGE MASS SPECTROMETRY; SOLUTION RESIDUE ANALYSIS; ISOTOPE DILUTION; INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY;
D O I
10.1039/ja9940900083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of isotope dilution (ID) to glow discharge mass spectrometry (GDMS) has been evaluated. Initial work with the analysis of solution residues has been modified to accommodate introduction of an isotopic spike. In evaluating ID-GDMS, elemental lead concentrations were determined in oil leachate samples. After equilibration of the sample and spike, a few hundred microliter volume of solution was mixed with a conducting host matrix. This slurry was then dried, homogenized and pressed into a GD cathode; after electrode formation, routine GDMS analysis (isotopic) was performed. Internal precision (within sample variation) was estimated to be better than 5% relative standard deviation (RSD) (1sigma) through the use of a computer model of the ID equation. External precision (between-sample variation) was better than 2% RSD (1sigma), a substantial improvement over most conventional GDMS analyses. For comparison purposes (i.e., where multiple isotopic spikes are impractical), a calibration curve was applied to the same data and gave external precision of better than 15% RSD. Both calibration curve and ID results compare well with those obtained by inductively coupled plasma atomic emission spectrometry.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 50 条
  • [1] ISOTOPE-DILUTION ANALYSIS THROUGH SPARK DISCHARGE MASS-SPECTROMETRY
    DIETZE, HJ
    OPAUSZKY, I
    ISOTOPENPRAXIS, 1979, 15 (10): : 309 - 312
  • [2] ISOTOPE-DILUTION MASS-SPECTROMETRY
    HEUMANN, KG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 : 575 - 592
  • [3] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    HESS, KR
    MARCUS, RK
    KING, FL
    ANALYTICAL CHEMISTRY, 1986, 58 (02) : A341 - &
  • [4] GLOW-DISCHARGE MASS-SPECTROMETRY
    HARRISON, WW
    BENTZ, BL
    PROGRESS IN ANALYTICAL SPECTROSCOPY, 1988, 11 (01): : 53 - 110
  • [5] APPLICATION OF GLOW-DISCHARGE MASS-SPECTROMETRY TO TRACE ANALYSIS OF METAL SAMPLES
    CHIBA, K
    ONO, A
    SAEKI, M
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1987, 27 (02) : B39 - B39
  • [6] ANALYSIS OF SOILS BY GLOW-DISCHARGE MASS-SPECTROMETRY
    DUCKWORTH, DC
    BARSHICK, CM
    SMITH, DH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 875 - 879
  • [7] ANALYSIS OF SOLIDS BY GLOW-DISCHARGE MASS-SPECTROMETRY
    WEBB, PM
    SANDERSON, NE
    ELECTRONICS & WIRELESS WORLD, 1987, 93 (1620): : 997 - 999
  • [8] GLOW-DISCHARGE MASS-SPECTROMETRY FOR ELEMENTAL ANALYSIS
    COBURN, JW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, : 68 - 68
  • [9] ISOTOPE-DILUTION MASS-SPECTROMETRY FOR PROCAINE DETERMINATION IN BIOLOGICAL SAMPLES
    CULEA, M
    PALIBRODA, N
    CHIRIAC, M
    MOLDOVAN, Z
    ABRAHAM, AD
    FRANGOPOL, PT
    BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (11) : 740 - 742
  • [10] ISOTOPE RATIO MEASUREMENTS USING GLOW-DISCHARGE MASS-SPECTROMETRY
    RICIPUTI, LR
    DUCKWORTH, DC
    BARSHICK, CM
    SMITH, DH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 146 : 55 - 64