RESPIRATORY GATING IN MAGNETIC-RESONANCE-IMAGING - IMPROVED IMAGE QUALITY OVER NONGATED IMAGES FOR EQUAL SCAN TIME

被引:10
作者
GROCH, MW
TURNER, DA
ERWIN, WD
机构
[1] RUSH PRESBYTERIAN ST LUKES MED CTR,DEPT DIAGNOST RADIOL & NUCL MED,MED PHYS SECT,CHICAGO,IL 60612
[2] RUSH PRESBYTERIAN ST LUKES MED CTR,DEPT DIAGNOST RADIOL & NUCL MED,MAGNET RESONANCE SECT,CHICAGO,IL 60612
关键词
MAGNETIC RESONANCE IMAGING; RESPIRATORY GATING; ECG RESPIRATORY GATING;
D O I
10.1016/0899-7071(91)90077-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance image quality is adversely affected by respiratory (RESP) motion during the scan. Respiratory gating improves magnetic resonance image (MRI) quality and removes artifacts, but has not been widely used, as RESP gating increases scan time. Our RESP-gating device was used to study scan time versus improvement in image quality using various gating modes; with and without combined electrocardiographic (ECG) gating. When RESP scans were acquired for the same time as non-gated scans, by using a wide RESP-gating window bracketing end expiration and a reduced number of pulse sequence repetitions, substantial improvement in image quality (over non-gated scans) resulted, despite the inferior statistical content of the acquisition.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 12 条
  • [1] PRELIMINARY EXPERIMENTAL RESULTS IN HUMANS AND ANIMALS WITH A SUPERCONDUCTING, WHOLE-BODY, NUCLEAR MAGNETIC-RESONANCE SCANNER
    ALFIDI, RJ
    HAAGA, JR
    ELYOUSEF, SJ
    BRYAN, PJ
    FLETCHER, BD
    LIPUMA, JP
    MORRISON, SC
    KAUFMAN, B
    RICHEY, JB
    HINSHAW, WS
    KRAMER, DM
    YEUNG, HN
    COHEN, AM
    BUTLER, HE
    AMENT, AE
    LIEBERMAN, JM
    [J]. RADIOLOGY, 1982, 143 (01) : 175 - 181
  • [2] RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING
    BAILES, DR
    GILDERDALE, DJ
    BYDDER, GM
    COLLINS, AG
    FIRMIN, DN
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 835 - 838
  • [3] CARR HU, 1954, PHYS REV, V3, P630
  • [4] NUCLEAR MAGNETIC-RESONANCE WHOLE-BODY IMAGER OPERATING AT 3.5 KGAUSS
    CROOKS, L
    ARAKAWA, M
    HOENNINGER, J
    WATTS, J
    MCREE, R
    KAUFMAN, L
    DAVIS, PL
    MARGULIS, AR
    DEGROOT, J
    [J]. RADIOLOGY, 1982, 143 (01) : 169 - 174
  • [5] GROCH M W, 1984, Radiology, V153, P98
  • [6] HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
  • [7] PSEUDO-GATING - ELIMINATION OF PERIODIC MOTION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING WITHOUT GATING
    HAACKE, EM
    LENZ, GW
    NELSON, AD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) : 162 - 174
  • [8] MOTION ARTIFACT SUPPRESSION TECHNIQUE (MAST) FOR MR IMAGING
    PATTANY, PM
    PHILLIPS, JJ
    CHIU, LC
    LIPCAMON, JD
    DUERK, JL
    MCNALLY, JM
    MOHAPATRA, SN
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (03) : 369 - 377
  • [9] Peters T. M., 1984, Technology of Nuclear Magnetic Resonance. 14th Annual Symposium on the Sharing of Computer Programs and Technology, P15
  • [10] THE EFFECT OF MOTION ON TWO-DIMENSIONAL FOURIER TRANSFORMATION MAGNETIC-RESONANCE IMAGES
    SCHULTZ, CL
    ALFIDI, RJ
    NELSON, AD
    KOPIWODA, SY
    CLAMPITT, ME
    [J]. RADIOLOGY, 1984, 152 (01) : 117 - 121