INDOOR RADON CONCENTRATION MEASUREMENTS IN SOME SPANISH HOUSES AND DWELLINGS WITH PLASTIC NUCLEAR TRACK DETECTORS

被引:0
作者
BAIXERAS, C [1 ]
GARCIA, I [1 ]
FERNANDEZ, F [1 ]
DOMINGO, C [1 ]
VIDALQUADRAS, A [1 ]
PIESCH, E [1 ]
机构
[1] FORSCHUNGSZENTRUM JULICH, DIV HLTH PHYS, W-7500 KARLSRUHE 1, GERMANY
来源
NUCLEAR TRACKS AND RADIATION MEASUREMENTS | 1991年 / 19卷 / 1-4期
关键词
MAKROFOL; ELECTROCHEMICAL ETCHING; ALPHA TRACKS; DOSIMETER FOR RADON; CALIBRATION FACTOR; RADON CONCENTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive dosemeter, based on Makrofol ED track detectors covered with aluminized Mylar, enclosed in the Karlsruhe diffussion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a Am-241 source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the NRPB Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have, also, been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 3 条
[1]  
Urban M., 1981, Radiation Protection Dosimetry, V1, P97
[2]  
URBAN M, 1986, NUCL TRACKS RAD MEAS, V12, P685
[3]  
1987, ANN ICRP, V17, P1