A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer

被引:22
作者
Avkshtol, Vladimir [1 ]
Dong, Yanqun [1 ]
Hayes, Shelly B. [1 ]
Hallman, Mark A. [1 ]
Price, Robert A. [1 ]
Sobczak, Mark L. [1 ]
Horwitz, Eric M. [1 ]
Zaorsky, Nicholas G. [1 ]
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, 333 Cottman Ave, Philadelphia, PA 19111 USA
关键词
prostate cancer; stereotactic body radiation therapy; technology; quality of life;
D O I
10.2147/RRU.S58262
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low-and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (<6% grade 3-4 late toxicities). Other outcomes (eg, overall and cancer-specific mortality) cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (similar to 15 minutes for gantry vs similar to 45 minutes for robotic arm), and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.
引用
收藏
页码:145 / 158
页数:14
相关论文
共 85 条
[1]   UPDATE OF DUTCH MULTICENTER DOSE-ESCALATION TRIAL OF RADIOTHERAPY FOR LOCALIZED PROSTATE CANCER [J].
Al-Mamgani, Abrahim ;
van Putten, Wim L. J. ;
Heemsbergen, Wilma D. ;
van Leenders, Geert J. L. H. ;
Slot, Annerie ;
Dielwart, Michel F. H. ;
Incrocci, Luca ;
Lebesque, Joos V. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04) :980-988
[2]   70 GY VERSUS 80 GY IN LOCALIZED PROSTATE CANCER: 5-YEAR RESULTS OF GETUG 06 RANDOMIZED TRIAL [J].
Beckendorf, Veronique ;
Guerif, Stephane ;
Le Prise, Elisabeth ;
Cosset, Jean-Marc ;
Bougnoux, Agnes ;
Chauvet, Bruno ;
Salem, Naji ;
Chapet, Olivier ;
Bourdain, Sylvain ;
Bachaud, Jean-Marc ;
Maingon, Philippe ;
Hannoun-Levi, Jean-Michel ;
Malissard, Luc ;
Simon, Jean-Marc ;
Pommier, Pascal ;
Hay, Men ;
Dubray, Bernard ;
Lagrange, Jean-Leon ;
Luporsi, Elisabeth ;
Bey, Pierre .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04) :1056-1063
[3]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[4]   SBRT for the primary treatment of localized prostate cancer: the effect of Gleason score, dose and heterogeneity of intermediate risk on outcome utilizing 2.2014 NCCN risk stratification guidelines [J].
Bernetich, Matthew ;
Oliai, Caspian ;
Lanciano, Rachelle ;
Hanlon, Alexandra ;
Lamond, John ;
Arrigo, Stephen ;
Yang, Jun ;
Good, Michael ;
Feng, Jing ;
Brown, Royce ;
Garber, Bruce ;
Mooreville, Michael ;
Brady, Luther W. .
FRONTIERS IN ONCOLOGY, 2014, 4
[5]   Phase I Dose-Escalation Study of Stereotactic Body Radiation Therapy for Low- and Intermediate-Risk Prostate Cancer [J].
Boike, Thomas P. ;
Lotan, Yair ;
Cho, L. Chinsoo ;
Brindle, Jeffrey ;
DeRose, Paul ;
Xie, Xian-Jin ;
Yan, Jingsheng ;
Foster, Ryan ;
Pistenmaa, David ;
Perkins, Alida ;
Cooley, Susan ;
Timmerman, Robert .
JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (15) :2020-2026
[6]   A single-center study of 100 consecutive patients with localized prostate cancer treated with stereotactic body radiotherapy [J].
Bolzicco, Giampaolo ;
Favretto, Maria Silvia ;
Satariano, Ninfa ;
Scremin, Enrico ;
Tambone, Carmelo ;
Tasca, Andrea .
BMC UROLOGY, 2013, 13
[7]  
Brenner DJ, 2002, INT J RADIAT ONCOL, V52, P6
[8]   Total error shift patterns for daily CT on rails image-guided radiotherapy to the prostate bed [J].
Cavalieri, Ronaldo ;
Gay, Hiram A. ;
Liu, Jingxia ;
Ferreira, Maria C. ;
Mota, Helvecio C. ;
Sibata, Claudio H. ;
Allison, Ron R. .
RADIATION ONCOLOGY, 2011, 6
[9]  
Centers for Medicare & Medicaid Services, 2012, PHYS FEE SCHEDULE
[10]   A retrospective analysis illustrating the substantial clinical and economic burden of prostate cancer [J].
Crawford, E. D. ;
Black, L. ;
Eaddy, M. ;
Kruep, E. J. .
PROSTATE CANCER AND PROSTATIC DISEASES, 2010, 13 (02) :162-167