GRANULOMA AFTER AUGMENTATION OF THE EYELIDS WITH LIQUID SILICONE - AN ELECTRON-MICROSCOPIC STUDY

被引:11
作者
AMEMIYA, T
DAKE, Y
机构
[1] Department of Ophthalmology, Nagasaki University School of Medicine, Nagasaki
关键词
SILICONE; GRANULOMA; LID PLASTIC SURGERY; X-RAY ANALYSIS; ENERGY DISPERSIVE; ELECTRON MICROSCOPY;
D O I
10.1097/00002341-199403000-00011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Granuloma after liquid silicone augmentation of the upper eyelids was studied by light and electron microscopy and energy dispersive x-ray analysis. Light microscopy showed proliferation of collagen fibers and many phagocytic macrophages with vacuoles. Electron microscopy showed many vacuoles in phagocytic macrophages, fragmentary myofibrils, and proliferation of collagen fibers. Vacuoles in phagocytic macrophages contained silicone that was demonstrated by energy dispersive x-ray analysis. The present case suggests that liquid silicone injection in the eyelid can induce degeneration of the orbicularis oculi muscle in addition to granuloma formation.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 15 条
[1]  
Travis W.D., Balogh K., Abraham J.L., Silicone granulomas: Report of three cases and review of the literature, Hum Pathol, 16, pp. 19-27, (1985)
[2]  
Kircher T., Silicone lymphadenopathy. A complication of silicone elastomer finger joint prostheses, Hum Pathol, 11, pp. 240-244, (1980)
[3]  
Ben-Hur N., Ballantyne D.L., Rees T.D., Seidman I., Local and systemic effects of dimethylpolysiloxane fluid in mice, Plast Reconstr Surg, 39, pp. 423-426, (1967)
[4]  
Nosanchuk J.S., Silicone granuloma in breast, Arch Surg, 97, pp. 583-585, (1968)
[5]  
Delage C., Shane J.J., Johnson F.B., Mammary silicone granuloma. Migration of silicone fluid to abdominal wall and inguinal region, Arch Dermatol, 108, pp. 104-107, (1973)
[6]  
Christie A.J., Weinberger K.A., Dietrich M., Silicone lymphadenopathy and synovitis. Complications of silicone elastomer finger joint prostheses, JAMA, 237, pp. 1463-1464, (1977)
[7]  
Hausner R.J., Schoen F.J., Pierson K.K., Foreign-body reaction to silicone gel in axillary lymph nodes after an augmentation mammaplasty, Plast Reconstr Surg, 62, pp. 381-384, (1978)
[8]  
Digby J.M., Wells A.L., Malignant lymphoma with intranodal refractile particles after insertion of silicone prostheses, Lancet, 2, (1981)
[9]  
Benjamin E., Ahmed A., Rashid A., Wright D.H., Silicone lymphadenopathy: A report of two cases, one with concomitant malignant lymphoma, Diagn Histopathol, 15, pp. 133-141, (1982)
[10]  
Kumagai Y., Shiokawa Y., Medsger T.A., Rodnan G.P., Clinical spectrum of connective tissue disease after cosmetic surgery: Observation on 18 patients and a review of the Japanese literature, Arthritis Rheum, 27, pp. 1-12, (1984)