Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography

被引:41
|
作者
Solomon, Justin [1 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ Hlth Syst, Dept Radiol, Carl E Ravin Adv Imaging Labs, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Clin Imaging Phys Grp, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[3] Duke Univ, Pratt Sch Engn, Dept Biomed Engn, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[4] Duke Univ, Pratt Sch Engn, Dept Elect & Comp Engn, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
关键词
image quality; computed tomography; observer models; detectability;
D O I
10.1117/1.JMI.3.3.035506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare computed tomography (CT) low-contrast detectability from human readers with observer model-based surrogates of image quality. A phantom with a range of low-contrast signals (five contrasts, three sizes) was imaged on a state-of-the-art CT scanner (Siemens' force). Images were reconstructed using filtered back projection and advanced modeled iterative reconstruction and were assessed by 11 readers using a two alternative forced choice method. Concurrently, contrast-to-noise ratio (CNR), area-weighted CNR (CNRA), and observer model-based metrics were estimated, including nonprewhitening (NPW) matched filter, NPW with eye filter (NPWE), NPW with internal noise, NPW with an eye filter and internal noise (NPWEi), channelized Hotelling observer (CHO), and CHO with internal noise (CHOi). The correlation coefficients (Pearson and Spearman), linear discriminator error, E, and magnitude of confidence intervals, vertical bar CI95%vertical bar, were used to determine correlation, proper characterization of the reconstruction algorithms, and model precision, respectively. Pearson (Spearman) correlation was 0.36 (0.33), 0.83 (0.84), 0.84 (0.86), 0.86 (0.88), 0.86 (0.91), 0.88 (0.90), 0.85 (0.89), and 0.87 (0.84), E was 0.25, 0.15, 0.2, 0.25, 0.3, 0.25, 0.4, and 0.45, and vertical bar CI95%vertical bar was 2.84 x 10(-3), 5.29 x 10(-3), 4.91 x 10(-3), 4.55 x 10(-3), 2.16 x 10(-3), 1.24 x 10(-3), 4.58 x 10-2, and 7.95 x 10-2 for CNR, CNRA, NPW, NPWE, NPWi, NPWEi, CHO, and CHOi, respectively. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A Process Model for Direct Correlation between Computed Tomography and Histopathology: Application in Lung Cancer
    Sieren, Jessica C.
    Weydert, Jamie
    Namati, Eman
    Thiesse, Jacqueline
    Sieren, Jered P.
    Reinhardt, Joseph M.
    Hoffman, Eric A.
    McLennan, Geoffrey
    ACADEMIC RADIOLOGY, 2010, 17 (02) : 169 - 180
  • [42] Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction
    Patrick J. Millerd
    Robert G. Paden
    Jeffrey T. Lund
    Amy K. Hara
    Wendy L. Stiles
    Miao He
    Qing Wu
    C. Daniel Johnson
    Abdominal Imaging, 2015, 40 : 1183 - 1189
  • [43] Validation of deep-learning image reconstruction for coronary computed tomography angiography: Impact on noise, image quality and diagnostic accuracy
    Benz, Dominik C.
    Benetos, Georgios
    Rampidis, Georgios
    von Felten, Elia
    Bakula, Adam
    Sustar, Aleksandra
    Kudura, Ken
    Messerli, Michael
    Fuchs, Tobias A.
    Gebhard, Catherine
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (05) : 444 - 451
  • [44] The accuracy of computed tomography-based linear measurements of human femora and titanium stem
    Feng, ZD
    Ziv, I
    Rho, J
    INVESTIGATIVE RADIOLOGY, 1996, 31 (06) : 333 - 337
  • [45] Attenuation-Based Automatic Kilovolt Selection in Abdominal Computed Tomography Effects on Radiation Exposure and Image Quality
    Eller, Achim
    May, Matthias S.
    Scharf, Michael
    Schmid, Axel
    Kuefner, Michael
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (10) : 559 - 565
  • [46] Harmonization of technical image quality in computed tomography: comparison between different reconstruction algorithms and kernels from six scanners
    Juntunen, Mikael A. K.
    Rautiainen, Jari
    Hanninen, Nina E.
    Kotiaho, Antti O.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (03):
  • [47] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Ha, Seongmin
    Kim, Woo Sun
    Kim, In-One
    PEDIATRIC RADIOLOGY, 2016, 46 (03) : 303 - 315
  • [48] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Young Jin Ryu
    Young Hun Choi
    Jung-Eun Cheon
    Seongmin Ha
    Woo Sun Kim
    In-One Kim
    Pediatric Radiology, 2016, 46 : 303 - 315
  • [49] Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    Haiter-Neto, F.
    Wenzel, A.
    Gotfredsen, E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 18 - 22
  • [50] Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite
    Jones, Aaron K.
    Odisio, Bruno C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 121 - 127