Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography

被引:41
|
作者
Solomon, Justin [1 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ Hlth Syst, Dept Radiol, Carl E Ravin Adv Imaging Labs, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Clin Imaging Phys Grp, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[3] Duke Univ, Pratt Sch Engn, Dept Biomed Engn, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
[4] Duke Univ, Pratt Sch Engn, Dept Elect & Comp Engn, 2424 Erwin Rd,Suite 302, Durham, NC 27705 USA
关键词
image quality; computed tomography; observer models; detectability;
D O I
10.1117/1.JMI.3.3.035506
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare computed tomography (CT) low-contrast detectability from human readers with observer model-based surrogates of image quality. A phantom with a range of low-contrast signals (five contrasts, three sizes) was imaged on a state-of-the-art CT scanner (Siemens' force). Images were reconstructed using filtered back projection and advanced modeled iterative reconstruction and were assessed by 11 readers using a two alternative forced choice method. Concurrently, contrast-to-noise ratio (CNR), area-weighted CNR (CNRA), and observer model-based metrics were estimated, including nonprewhitening (NPW) matched filter, NPW with eye filter (NPWE), NPW with internal noise, NPW with an eye filter and internal noise (NPWEi), channelized Hotelling observer (CHO), and CHO with internal noise (CHOi). The correlation coefficients (Pearson and Spearman), linear discriminator error, E, and magnitude of confidence intervals, vertical bar CI95%vertical bar, were used to determine correlation, proper characterization of the reconstruction algorithms, and model precision, respectively. Pearson (Spearman) correlation was 0.36 (0.33), 0.83 (0.84), 0.84 (0.86), 0.86 (0.88), 0.86 (0.91), 0.88 (0.90), 0.85 (0.89), and 0.87 (0.84), E was 0.25, 0.15, 0.2, 0.25, 0.3, 0.25, 0.4, and 0.45, and vertical bar CI95%vertical bar was 2.84 x 10(-3), 5.29 x 10(-3), 4.91 x 10(-3), 4.55 x 10(-3), 2.16 x 10(-3), 1.24 x 10(-3), 4.58 x 10-2, and 7.95 x 10-2 for CNR, CNRA, NPW, NPWE, NPWi, NPWEi, CHO, and CHOi, respectively. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Generalized Gaussian model-based reconstruction method of computed tomography image from fewer projections
    Md. Shafiqul Islam
    Rafiqul Islam
    Signal, Image and Video Processing, 2020, 14 : 547 - 555
  • [12] Generalized Gaussian model-based reconstruction method of computed tomography image from fewer projections
    Islam, Md. Shafiqul
    Islam, Rafiqul
    SIGNAL IMAGE AND VIDEO PROCESSING, 2020, 14 (03) : 547 - 555
  • [13] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Gonca Koc
    Jesse L. Courtier
    Andrew Phelps
    Peter A. Marcovici
    John D. MacKenzie
    Pediatric Radiology, 2014, 44 : 787 - 794
  • [14] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Koc, Gonca
    Courtier, Jesse L.
    Phelps, Andrew
    Marcovici, Peter A.
    MacKenzie, John D.
    PEDIATRIC RADIOLOGY, 2014, 44 (07) : 787 - 794
  • [15] Correlation between human and model observer performance for discrimination task in CT
    Zhang, Yi
    Leng, Shuai
    Yu, Lifeng
    Carter, Rickey E.
    McCollough, Cynthia H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) : 3389 - 3404
  • [16] Correlation between human observer performance and model observer performance in differential phase contrast CT
    Li, Ke
    Garrett, John
    Chen, Guang-Hong
    MEDICAL PHYSICS, 2013, 40 (11)
  • [17] Physical model-based contrast enhancement of computed tomography images
    Chen, Yi-Wen
    Shih, Cheng-Ting
    Lin, Hsin-Hon
    Chuang, Keh-Shih
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2016, : 238 - 241
  • [18] Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction
    Millerd, Patrick J.
    Paden, Robert G.
    Lund, Jeffrey T.
    Hara, Amy K.
    Stiles, Wendy L.
    He, Miao
    Wu, Qing
    Johnson, C. Daniel
    ABDOMINAL IMAGING, 2015, 40 (05): : 1183 - 1189
  • [19] Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain
    Leng, Shuai
    Yu, Lifeng
    Zhang, Yi
    Carter, Rickey
    Toledano, Alicia Y.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [20] Correlation between Model Observer and Human Observer Performance in CT Imaging when Lesion Location is Uncertain
    Leng, Shuai
    Yu, Lifeng
    Chen, Lingyun
    Giraldo, Juan C. Ramirez
    McCollough, Cynthia H.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313