摘要
The purpose of this study was to compare computed tomography (CT) low-contrast detectability from human readers with observer model-based surrogates of image quality. A phantom with a range of low-contrast signals (five contrasts, three sizes) was imaged on a state-of-the-art CT scanner (Siemens' force). Images were reconstructed using filtered back projection and advanced modeled iterative reconstruction and were assessed by 11 readers using a two alternative forced choice method. Concurrently, contrast-to-noise ratio (CNR), area-weighted CNR (CNRA), and observer model-based metrics were estimated, including nonprewhitening (NPW) matched filter, NPW with eye filter (NPWE), NPW with internal noise, NPW with an eye filter and internal noise (NPWEi), channelized Hotelling observer (CHO), and CHO with internal noise (CHOi). The correlation coefficients (Pearson and Spearman), linear discriminator error, E, and magnitude of confidence intervals, vertical bar CI95%vertical bar, were used to determine correlation, proper characterization of the reconstruction algorithms, and model precision, respectively. Pearson (Spearman) correlation was 0.36 (0.33), 0.83 (0.84), 0.84 (0.86), 0.86 (0.88), 0.86 (0.91), 0.88 (0.90), 0.85 (0.89), and 0.87 (0.84), E was 0.25, 0.15, 0.2, 0.25, 0.3, 0.25, 0.4, and 0.45, and vertical bar CI95%vertical bar was 2.84 x 10(-3), 5.29 x 10(-3), 4.91 x 10(-3), 4.55 x 10(-3), 2.16 x 10(-3), 1.24 x 10(-3), 4.58 x 10-2, and 7.95 x 10-2 for CNR, CNRA, NPW, NPWE, NPWi, NPWEi, CHO, and CHOi, respectively. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Model-based computed tomography image estimation: partitioning approach
    Bayisa, Fekadu L.
    Yu, Jun
    JOURNAL OF APPLIED STATISTICS, 2019, 46 (14) : 2627 - 2648
  • [2] Comparison of quantitative image quality of cardiac computed tomography between raw-data-based and model-based iterative reconstruction algorithms with an emphasis on image sharpness
    Lee, Ki Baek
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2020, 50 (11) : 1570 - 1578
  • [3] Comparison of quantitative image quality of cardiac computed tomography between raw-data-based and model-based iterative reconstruction algorithms with an emphasis on image sharpness
    Ki Baek Lee
    Hyun Woo Goo
    Pediatric Radiology, 2020, 50 : 1570 - 1578
  • [4] Effect of Model-Based Iterative Reconstruction on Image Quality of Chest Computed Tomography for COVID-19 Pneumonia
    Liu, Caiyin
    Lin, Junkun
    Chen, Yingjie
    Hu, Yingfeng
    Wu, Ruzhen
    Lin, Xuejun
    Xu, Rulin
    Zhong, Zhiping
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (06) : 936 - 942
  • [5] Update on the non-prewhitening model observer in computed tomography for the assessment of the adaptive statistical and model-based iterative reconstruction algorithms
    Ott, Julien G.
    Becce, Fabio
    Monnin, Pascal
    Schmidt, Sabine
    Bochud, Francois O.
    Verdun, Francis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15) : 4047 - 4064
  • [6] Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography
    Kuo, Yu
    Lin, Yi-Yang
    Lee, Rheun-Chuan
    Lin, Chung-Jung
    Chiou, Yi-You
    Guo, Wan-Yuo
    MEDICINE, 2016, 95 (31)
  • [7] Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography
    Yukako Nishiyama
    Keiji Tada
    Yuichi Nishiyama
    Hiroshi Mori
    Mitsunari Maruyama
    Takashi Katsube
    Nobuko Yamamoto
    Hidekazu Kanayama
    Yasushi Yamamoto
    Hajime Kitagaki
    Pediatric Radiology, 2016, 46 : 1663 - 1670
  • [8] Patient dose optimization for computed radiography using physical and observer-based measurements as image quality metrics
    Freitas, Marcelo B.
    Pimentel, Ricardo B.
    Braga, Laura F.
    Salido, Francisco S. A.
    Neves, Rodrigo F. C. A.
    Medeiros, Regina B.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [9] Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography
    Nishiyama, Yukako
    Tada, Keiji
    Nishiyama, Yuichi
    Mori, Hiroshi
    Maruyama, Mitsunari
    Katsube, Takashi
    Yamamoto, Nobuko
    Kanayama, Hidekazu
    Yamamoto, Yasushi
    Kitagaki, Hajime
    PEDIATRIC RADIOLOGY, 2016, 46 (12) : 1663 - 1670
  • [10] Deep-learning-based model observer for a lung nodule detection task in computed tomography
    Gong, Hao
    Hu, Qiyuan
    Walther, Andrew
    Koo, Chi Wan
    Takahashi, Edwin A.
    Levin, David L.
    Johnson, Tucker F.
    Hora, Megan J.
    Leng, Shuai
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (04)