NOSOCOMIAL BLOOD-BORNE INFECTION SECONDARY TO INTRAVASCULAR DEVICES

被引:29
作者
FRY, DE
FRY, RV
BORZOTTA, AP
机构
[1] VET ADM MED CTR,CLEVELAND,OH
[2] CASE WESTERN RESERVE UNIV,DEPT SURG,CLEVELAND,OH 44106
关键词
D O I
10.1016/0002-9610(94)90090-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
A total of 113 patients with 159 episodes of intravascular device, blood-borne infection were studied. All infections were confirmed by the same organism being recovered from blood culture and by semiquantitative culture of the catheter tip. Sites of infection included the peripheral venous line (n = 72), central catheter (n = 49), arterial line (n = 18), subclavian dialysis catheter (n = 12), Swan-Ganz catheter (n = 4), Broviac catheter (n = 3), and transvenous pacemaker wires (n = 1). Staphylococcus aureus (n = 78) and Staphylococcus epidermidis (n = 33) predominated as pathogens. Excessive length of catheterization was implicated as directly responsible for this complication in patients with peripheral intravenous and arterial lines. Nosocomial staphylococcal bacteremia must be considered secondary to an indwelling intravascular device until proven otherwise. Appropriate therapy requires removal of the catheters, excision of tile vein if suppuration or persistent bacteremia is identified, and specific antibiotic therapy.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 24 条
[1]  
BENEZRA D, 1988, AM J MED, V85, P495
[2]  
BOZZETTI F, 1985, SURG GYNECOL OBSTET, V161, P293
[3]   INFECTIOUS COMPLICATIONS OF INDWELLING LONG-TERM CENTRAL VENOUS CATHETERS [J].
CLARKE, DE ;
RAFFIN, TA .
CHEST, 1990, 97 (04) :966-972
[4]   RAPID DIAGNOSIS OF INTRAVASCULAR CATHETER-ASSOCIATED INFECTION BY DIRECT GRAM STAINING OF CATHETER SEGMENTS [J].
COOPER, GL ;
HOPKINS, CC .
NEW ENGLAND JOURNAL OF MEDICINE, 1985, 312 (18) :1142-1147
[5]   COMPLICATIONS OF PULMONARY-ARTERY CATHETERIZATION IN THE CARE OF CRITICALLY ILL PATIENTS - PROSPECTIVE-STUDY [J].
ELLIOTT, CG ;
ZIMMERMAN, GA ;
CLEMMER, TP .
CHEST, 1979, 76 (06) :647-652
[6]  
FRY DE, 1987, AM SURGEON, V53, P438
[7]   PERCUTANEOUS INDWELLING RADIAL-ARTERY CATHETERS FOR MONITORING CARDIOVASCULAR FUNCTION - PROSPECTIVE STUDY OF RISK OF THROMBOSIS AND INFECTION [J].
GARDNER, RM ;
SCHWARTZ, R ;
WONG, HC ;
BURKE, JP .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (22) :1227-1231
[8]   CATHETER-ASSOCIATED SEPTIC THROMBOPHLEBITIS [J].
GARRISON, RN ;
RICHARDSON, JD ;
FRY, DE .
SOUTHERN MEDICAL JOURNAL, 1982, 75 (08) :917-919
[9]  
KAEBNICK HW, 1987, SURGERY, V102, P756
[10]   REDUCED INTRAVASCULAR CATHETER INFECTION BY ANTIBIOTIC BONDING - A PROSPECTIVE, RANDOMIZED, CONTROLLED TRIAL [J].
KAMAL, GD ;
PFALLER, MA ;
REMPE, LE ;
JEBSON, PJR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (18) :2364-2368