Onset of Nucleate Boiling Detection in a Boiler Tube by Wavelet Transformation of Vibration Signals

被引:0
作者
Nikravesh, Seyed Majid Yadavar [1 ]
Taheri, Hossein [2 ,3 ]
机构
[1] Shahid Beheshti Univ, Dept Mech Engn, Tehran 1658953571, Iran
[2] Iowa State Univ, Ctr Nondestruct Evaluat CNDE, Ames, IA 50011 USA
[3] Iowa State Univ, Mech Engn Dept, Ames, IA 50011 USA
来源
JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS | 2018年 / 1卷 / 03期
关键词
wavelet transform; acoustics; vibration; onset of nucleate boiling (ONB); boiler; nondestructive evaluation;
D O I
10.1115/1.4039939
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Condition monitoring and fault diagnosis techniques are increasingly used for assurance of machine condition and safe operation of the systems and structures. For this purpose, preliminary data about the machine performance are obtained from the system and signal processing techniques are used to extract features and final information regarding the machine performance. One type of the primary data that can be obtained from a system is the vibration responses of the system. Vibration responses of dynamical systems are usually nonstationary signals. In boilers and heat exchangers, generation and collapse of the vapor bubbles due to overheating can generate vibration in the tubes. These vibrations could be detected and identified in terms of location and time of occurrence for future maintenance and modification of the system and process. In this paper, a nonstationary vibration analysis method based on Morlet wavelet transform is presented for detection of onset of nucleate boiling (ONB) in a boiler tube. Comparison of the results by wavelet transform and visual observation of the ONB shows the capability and accuracy (less than 3% difference) of the proposed technique for detection of ONB in a boiler tube.
引用
收藏
页数:7
相关论文
共 18 条
  • [1] Onset of Nucleate Boiling for subcooled flow through a one-side heated narrow rectangular channel
    Al-Yahia, Omar S.
    Jo, Daeseong
    [J]. ANNALS OF NUCLEAR ENERGY, 2017, 109 : 30 - 40
  • [2] Onset of nucleate boiling and active nucleation site density during subcooled flow boiling
    Basu, N
    Warrier, GR
    Dhir, VK
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 717 - 728
  • [3] Blevins R.D., 1990, FLOW INDUCED VIBRATI
  • [4] Boufenar M, 2012, CONDITION MONITORING OF MACHINERY IN NON-STATIONARY OPERATIONS, P239
  • [5] Experimental evaluation of the onset of subcooled flow boiling at high liquid velocity and subcooling
    Celata, GP
    Cumo, M
    Mariani, A
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (12) : 2879 - 2885
  • [6] de Castro A. J. A., 2001, J BRAZ SOC MECH SCI, V23, P513
  • [7] Gaberson HA, 2002, SOUND VIB, V36, P12
  • [8] Hsu Y.Y., 1962, J HEAT TRANSF, V84, P207, DOI [10.1115/1.3684339, DOI 10.1115/1.3684339]
  • [9] Fault diagnosis of rotating machinery based on improved wavelet package transform and SVMs ensemble
    Hu, Qiao
    He, Zhengjia
    Zhang, Zhousuo
    Zi, Yanyang
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2007, 21 (02) : 688 - 705
  • [10] Nikravesh S. M. Y., 2013, V014T15A022 ASME