SODIUM-SELECTIVE LIQUID ION-EXCHANGER MICRO-ELECTRODES FOR INTRACELLULAR MEASUREMENTS

被引:71
作者
ODOHERTY, J
GARCIADIAZ, JF
ARMSTRONG, WM
机构
关键词
D O I
10.1126/science.424756
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The sodium-selective ligand 1,1,1-tris[11-(21-oxa- 41-oxo-51-aza-51-methyl) dodecanyl]propane dissolved in 3-nitro-o-xylene containing a small amount of the lipophilic anion tetrachlorophenyl borate was used as a liquid ion-exchanger in sodium-selective microelectrodes. The microelectrodes gave rapid, stable responses that were linear functions of the logarithm of sodium activity. They were tested under conditions approximating those to be expected in the cell interior, and the results indicated that they can be used to measure intracellular sodium activity without significant interference from intracellular potassium. Copyright © 1979 AAAS.
引用
收藏
页码:1349 / 1351
页数:3
相关论文
共 50 条
[41]   INVESTIGATION OF ION-EXCHANGER MEMBRANE ELECTRODES REVERSIBLE TO HYDROGEN IONS [J].
KIRYUSHO.VN ;
GORDIEVS.AV ;
KOLESNIK.GS ;
TEVLINA, AS ;
SIVIDOVA, SN ;
SENTSOVA, TN .
INDUSTRIAL LABORATORY, 1968, 34 (07) :949-&
[42]   MICRODETERMINATION AND SEPARATION OF MANGANESE USING A LIQUID ION-EXCHANGER [J].
MENON, SK ;
AGRAWAL, YK .
ANALYST, 1986, 111 (03) :335-338
[43]   MICRODETERMINATION AND SEPARATION OF MOLYBDENUM USING A LIQUID ION-EXCHANGER [J].
MENON, SK ;
AGRAWAL, YK .
ANALYST, 1986, 111 (08) :911-914
[44]   SELECTIVE ION-EXCHANGER BEHAVIOR OF NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES [J].
HORVAI, G ;
HORVATH, V ;
FARKAS, A ;
PUNGOR, E .
TALANTA, 1989, 36 (03) :403-405
[45]   ION-SELECTIVE ELECTRODES AND INACCURATE SERUM SODIUM MEASUREMENTS [J].
BURGESS, ED ;
SCHNURR, LP ;
WILKES, P .
ANNALS OF INTERNAL MEDICINE, 1985, 103 (05) :806-806
[46]   MEASUREMENT OF SODIUM AND POTASSIUM ACTIVITIES IN SQUID AXON BY MEANS OF CATION-SELECTIVE GLASS MICRO-ELECTRODES [J].
HINKE, JA .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (02) :314-&
[47]   CYTOPLASMIC FREE MAGNESIUM IN NEURONS OF HELIX-ASPERSA MEASURED WITH ION-SELECTIVE MICRO-ELECTRODES [J].
ALVAREZLEEFMANS, FJ ;
GAMINO, SM ;
RINK, TJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1983, 345 (DEC) :P104-P104
[48]   Bismuth selective antimony(III) silicate inorganic ion-exchanger [J].
Reetha, C ;
Aravindakshan, KK ;
Janardanan, C .
INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2002, 41 (07) :1438-1440
[49]   APPLICATION OF PHOTOPOLYMERS FOR THE PREPARATION OF SODIUM-SELECTIVE AND POTASSIUM-SELECTIVE MATRIX MEMBRANE ELECTRODES [J].
MULLER, H ;
SPICKERMANN, A .
CHEMIA ANALITYCZNA, 1995, 40 (04) :599-608
[50]   SELECTIVE SEPARATION OF KETOSES AND ALDOSES BY CHROMATOGRAPHY ON A POLYETHYLENEIMINE ION-EXCHANGER [J].
BILIK, V ;
PETRUS, L ;
KUNIAK, L .
CHEMICKE ZVESTI, 1979, 33 (01) :118-122