SODIUM-SELECTIVE LIQUID ION-EXCHANGER MICRO-ELECTRODES FOR INTRACELLULAR MEASUREMENTS

被引:71
作者
ODOHERTY, J
GARCIADIAZ, JF
ARMSTRONG, WM
机构
关键词
D O I
10.1126/science.424756
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The sodium-selective ligand 1,1,1-tris[11-(21-oxa- 41-oxo-51-aza-51-methyl) dodecanyl]propane dissolved in 3-nitro-o-xylene containing a small amount of the lipophilic anion tetrachlorophenyl borate was used as a liquid ion-exchanger in sodium-selective microelectrodes. The microelectrodes gave rapid, stable responses that were linear functions of the logarithm of sodium activity. They were tested under conditions approximating those to be expected in the cell interior, and the results indicated that they can be used to measure intracellular sodium activity without significant interference from intracellular potassium. Copyright © 1979 AAAS.
引用
收藏
页码:1349 / 1351
页数:3
相关论文
共 50 条
[21]   VOLUME OF SARCOPLASMIC-RETICULUM IN RAT MUSCLE CALCULATED ON BASIS OF MEASUREMENTS MADE WITH ION-SELECTIVE MICRO-ELECTRODES [J].
MACDERMOTT, M ;
KERNAN, RP .
IRISH JOURNAL OF MEDICAL SCIENCE, 1978, 147 (09) :323-323
[22]   Experimental and theoretical study on cetylpyridinium dipicrylamide - A promising ion-exchanger for cetylpyridinium selective electrodes [J].
Fizer, Maksym ;
Fizer, Oksana ;
Sidey, Vasyl ;
Mariychuk, Ruslan ;
Studenyak, Yaroslav .
JOURNAL OF MOLECULAR STRUCTURE, 2019, 1187 :77-85
[24]   Donnan Failure of Ion-Selective Electrodes with Hydrophilic High-Capacity Ion-Exchanger Membranes [J].
Ogawara, Shogo ;
Carey, Jesse L., III ;
Zou, Xu U. ;
Bühlmann, Philippe .
ACS SENSORS, 2016, 1 (01) :95-101
[25]   ASSESSMENT OF POTASSIUM ZINC FERROCYANIDE AS AN ALKALI-METAL ION-EXCHANGER IN ION-SELECTIVE ELECTRODES [J].
FOGG, AG ;
PATHAN, AS ;
BURNS, DT .
ANALYTICAL LETTERS, 1974, 7 (8-9) :539-543
[26]   NITRATE ELECTRODE BASED ON A LIQUID ION-EXCHANGER [J].
GREKOVIC.AL ;
MATEROVA, EA ;
YURINSKA.VE .
ZHURNAL ANALITICHESKOI KHIMII, 1972, 27 (06) :1218-+
[27]   PREPARATION OF NEUTRAL SODIUM-SELECTIVE IONOPHORES AND THEIR CHARACTERIZATION IN MEMBRANE ELECTRODES [J].
BONGARDT, F ;
VOGTLE, F ;
WEGMANN, D ;
AMMANN, D ;
MARUIZUMI, T ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1987, 70 (01) :153-157
[28]   Effect of lipophilic ion-exchanger leaching on the detection limit of carrier-based ion-selective electrodes [J].
Telting-Diaz, M ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5582-5589
[29]   Mixed ion-exchanger chemically modified carbon paste ion-selective electrodes for determination of triprolidine hydrochloride [J].
Issa, Y. M. ;
Abu Attia, F. M. ;
Ismail, N. S. .
JOURNAL OF ADVANCED RESEARCH, 2010, 1 (01) :79-85
[30]   A NEW ION-EXCHANGER WITH HIGH INVIVO SODIUM CAPACITY [J].
MASON, NS ;
SPARKS, RE ;
SKOFF, H ;
LUBOWITZ, H ;
GULMEN, GB ;
MAZUMDAR, DC ;
LITT, MH .
KIDNEY INTERNATIONAL, 1985, :S178-S182