DETECTION OF MUONS WITH A LEAD SCINTILLATING-FIBER CALORIMETER

被引:15
|
作者
ACOSTA, D
BUONTEMPO, S
CALOBA, L
DESALVO, R
EREDITATO, A
FERRARI, R
FUMAGALLI, G
GOGGI, G
HAO, W
HENRIQUES, A
LINSSEN, L
LIVAN, M
MAIO, A
MONDARDINI, MR
ONG, B
PAAR, HP
PASTORE, F
PENNACCHIO, E
POGGIOLI, L
POLESELLO, G
RICCARDI, F
RIMOLDI, A
SCHEEL, CV
SEIXAS, JM
SIMON, A
SIVERTZ, M
SONDEREGGER, P
SOUZA, MN
THOME, ZD
VERCESI, V
WANG, Y
WIGMANS, R
XU, C
机构
[1] WORLDLAB,LAUSANNE,SWITZERLAND
[2] LIP,LISBON,PORTUGAL
[3] UNIV PARIS 06,PHYS NUCL & HAUTES ENERGIES LAB,PARIS,FRANCE
[4] NATL INST NUCL & HIGH ENERGY PHYS,AMSTERDAM,NETHERLANDS
[5] UNIV FED RIO DE JANEIRO,EE,COPPE,RIO JANEIRO,BRAZIL
[6] UNIV NAPLES,I-80138 NAPLES,ITALY
[7] IST NAZL FIS NUCL,NAPLES,ITALY
[8] IST NAZL FIS NUCL,PAVIA,ITALY
[9] CERN,LAA PROJECT,CH-1211 GENEVA 23,SWITZERLAND
[10] CORNELL UNIV,ITHACA,NY 14853
[11] UNIV CAGLIARI,I-09100 CAGLIARI,ITALY
[12] UNIV HEIDELBERG,W-6900 HEIDELBERG,GERMANY
[13] UNIV PARIS 07,F-75221 PARIS 05,FRANCE
[14] IST NAZL FIS NUCL,CAGLIARI,ITALY
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1992年 / 320卷 / 1-2期
关键词
D O I
10.1016/0168-9002(92)90772-V
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on an experimental study of the signals from high-energy (5-225 GeV) muons traversing a 9.5 interaction lengths deep electromagnetic/hadronic calorimeter consisting of lead and scintillating plastic fibers, constructed at CERN in the framework of the LAA project. The muons lose on average between 2.6 GeV (at 5 GeV) and 8.8 GeV (at 225 GeV) in this process. This energy loss can be measured with a precision of a fraction of a GeV in most of the events. Accuracy in the energy loss measurements is important since the rms spread in the energy loss of muons traversing this calorimeter is not smaller than approximately 6% at any energy. The nominal calibration constants, derived from the calorimeter response to electromagnetic showers, are found to be incorrect for the muon signals. On average, these calibration constants are between 40% (for low energy muons) and 15% (high energy) too high. The fiber bunches sticking out of the back plane of the calorimeter for readout purposes cause the muon signals to be position dependent. This can cause an anomalous enhancement of the muon signal of up to 35%. A moderate position resolution of approximately 1 cm is sufficient to correct for this effect. The e/mip ratio was found to be 0.72 +/- 0.03.
引用
收藏
页码:128 / 143
页数:16
相关论文
共 50 条
  • [1] ENERGY RESOLUTION OF A LEAD SCINTILLATING-FIBER ELECTROMAGNETIC CALORIMETER
    BUDAGOV, J
    CHIRIKOVZORIN, I
    GLAGOLEV, V
    JORDANOV, A
    KHARZHEEV, Y
    LIBA, I
    MALYUKOV, S
    RUSSAKOVICH, NA
    RUSSAKOVICH, NL
    SOLOVYEV, A
    ROHAC, J
    TOKAR, S
    PANTEA, D
    COX, B
    DUKES, E
    PARA, A
    CHLACHIDZE, G
    KHUBUA, J
    MINASHVILI, I
    ASLANIAN, E
    BAGDASAROV, S
    POGOSYAN, G
    BARAN, A
    LAVROVA, Z
    LEVIN, V
    POROSHIN, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 343 (2-3): : 476 - 483
  • [2] Test results of a fully projective lead/scintillating-fiber calorimeter
    Badier, J.
    Bouhemaid, N.
    Buontempo, S.
    Busson, P.
    Caloba, L.
    Cattaneo, P.
    Charlot, C.
    Chekhtman, A.
    Cousinou, M.C.
    Dagoret, S.
    dell'Acqua, A.
    Duchovni, E.
    Ereditato, A.
    Ferrari, R.
    Founchez, D.
    Fredj, L.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A337 (2-3) : 326 - 341
  • [3] Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
    李祖豪
    许伟伟
    王玲玉
    张诚
    唐志成
    严琪
    杨民
    吕雨生
    陈国明
    陈和生
    Chinese Physics C, 2014, (05) : 78 - 83
  • [4] Study of silicon photomultipliers for the readout of a lead/scintillating-fiber calorimeter
    Alemanno, F.
    Bernardini, P.
    Corvaglia, A.
    De Matteis, G.
    Martina, L.
    Miccoli, A.
    Panareo, M.
    Panetta, M. P.
    Pinto, C.
    Surdo, A.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (06):
  • [5] Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
    Li Zu-Hao
    Xu Wei-Wei
    Wang Ling-Yu
    Zhang Cheng
    Tang Zhi-Cheng
    Yan Qi
    Yang Min
    Lu Yu-Sheng
    Chen Guo-Ming
    Chen He-Sheng
    CHINESE PHYSICS C, 2014, 38 (05)
  • [6] Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
    李祖豪
    许伟伟
    王玲玉
    张诚
    唐志成
    严琪
    杨民
    吕雨生
    陈国明
    陈和生
    Chinese Physics C, 2014, 38 (05) : 78 - 83
  • [7] TEST-RESULTS OF A FULLY PROJECTIVE LEAD/SCINTILLATING-FIBER CALORIMETER
    BADIER, J
    BOUHEMAID, N
    BUONTEMPO, S
    BUSSON, P
    CALOBA, L
    CATTANEO, P
    CHARLOT, C
    CHEKHTMAN, A
    COUSINOU, MC
    DAGORET, S
    DELLACQUA, A
    DUCHOVNI, E
    EREDITATO, A
    FERRARI, R
    FOUCHEZ, D
    FREDJ, L
    FUMAGALLI, G
    GAILLARD, JM
    GOGGI, G
    GOMES, A
    HANSLKOZANECKA, T
    HENRIQUES, A
    JENNI, P
    KOVACS, F
    LELLOUCH, D
    LEVINSON, L
    LINSSEN, L
    LIVAN, M
    LORY, J
    LUPU, N
    MAIO, A
    MICHEL, B
    MIKENBERG, G
    MONTAROU, G
    NACASCH, R
    NAGY, E
    PALLIN, D
    PENNACCHIO, E
    PERALTA, L
    POGGIOLI, L
    POLESELLO, G
    RICCARDI, F
    RIMOLDI, A
    SEIXAS, JM
    SOUZA, MN
    THOME, ZD
    TISSERANT, S
    TOME, B
    VAZEILLE, F
    VERCESI, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 326 - 341
  • [8] THE PERFORMANCE OF A LEAD SCINTILLATING-FIBER CALORIMETER AT LHC SSC COMPATIBLE GATE WIDTHS
    ACOSTA, D
    AVELLINO, P
    BUONTEMPO, S
    CALOBA, L
    DESALVO, R
    EREDITATO, A
    FERRARI, R
    FUMAGALLI, G
    GOGGI, G
    HAO, W
    HENRIQUES, A
    LINSSEN, L
    LIVAN, M
    MAIO, A
    MONDARDINI, MR
    ONG, B
    PAAR, HP
    PASTORE, F
    PENNACCHIO, E
    POGGIOLI, L
    POLESELLO, G
    RICCARDI, F
    RIMOLDI, A
    SCHEEL, CV
    SEIXAS, JM
    SIMON, A
    SILVA, C
    SIVERTZ, M
    SONDEREGGER, P
    SOUZA, MN
    THOME, ZD
    VERCESI, V
    WANG, Y
    WIGMANS, R
    XU, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (03): : 431 - 449
  • [9] RD1 SCINTILLATING-FIBER CALORIMETER STUDIES
    LINSSEN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (01): : 73 - 84
  • [10] ON MUON PRODUCTION AND OTHER LEAKAGE ASPECTS OF PION ABSORPTION IN A LEAD SCINTILLATING-FIBER CALORIMETER
    ACOSTA, D
    BUONTEMPO, S
    CALOBA, L
    CARIA, M
    DESALVO, R
    EREDITATO, A
    FERRARI, R
    FUMAGALLI, G
    GOGGI, G
    HAO, W
    HARTJES, FG
    HENRIQUES, A
    LINSSEN, L
    LIVAN, M
    MAIO, A
    MAPELLI, L
    MONDARDINI, MR
    ONG, B
    PAAR, HP
    PASTORE, F
    PENNACCHIO, E
    POGGIOLI, L
    POLESELLO, G
    RICCARDI, F
    RIMOLDI, A
    SCHEEL, CV
    SCHMITZ, J
    SEIXAS, JM
    SIMON, A
    SIVERTZ, M
    SONDEREGGER, P
    SOUZA, MN
    THOME, ZD
    VERCESI, V
    WANG, Y
    WIGMANS, R
    XU, C
    YOU, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (1-2): : 143 - 159