A Postprocessing Method for Compensation of Scatter and Collimator Blurring in SPECT: A Proof-of-Concept Study

被引:1
作者
Yan, Yan [1 ]
Zeng, Gengsheng Lawrence [2 ]
机构
[1] Univ Utah, Dept Phys, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84132 USA
关键词
SPECT; scatter compensation; collimator blurring compensation; deblurring;
D O I
10.2967/jnmt.108.061135
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Attenuation, scatter, and blurring are 3 major contributors to SPECT image degradation. Image reconstruction without compensation for these degradations results in reduced contrast and reduced quantitative accuracy. In this proof-of-concept study, we present an efficient postprocessing method to compensate for the scatter and blurring effect in SPECT. Methods: A raw image is first reconstructed with attenuation correction only. Then, a 2-dimensional (2D) point spread function (PSF) in the image domain is estimated to model the scatter and blurring. This spatially variant 2D PSF is fitted with an asymmetric gaussian function. The accuracy of the estimated 2D PSF is compared with that estimated from the Monte Carlo simulations and the scatter response functions in the projection domain. A further-blurring-and-deconvolution method is used to restore images with the spatially variant 2D PSF. Results: The method is tested using computer simulations and a phantom experiment. The preliminary results demonstrate an improvement in image quality, with increased image contrast and quantitative accuracy, and the feasibility of this postprocessing method. Conclusion: We present a proof-of-concept study for a postprocessing method to compensate for scatter and blurring. Our results indicate that the method is a promising alternative to the state-of-the-art compensation methods thanks to its easy and fast implementation.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 34 条
[1]   A slice-by-slice blurring model and kernel evaluation using the Klein-Nishina formula for 3D scatter compensation in parallel and converging beam SPECT [J].
Bai, CY ;
Zeng, GSL ;
Gullberg, GT .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1275-1307
[2]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[3]   Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation [J].
Beekman, FJ ;
de Jong, HWAM ;
van Geloven, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :867-877
[4]   Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection [J].
de Jong, HWAM ;
Slijpen, ETP ;
Beekman, FJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :58-64
[5]   COMPENSATION FOR COLLIMATOR DIVERGENCE IN SPECT USING INVERSE MONTE-CARLO RECONSTRUCTION [J].
FLOYD, CE ;
JASZCZAK, RJ ;
MANGLOS, SH ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :784-787
[6]  
Frey E. C., 1996, 1996 IEEE Nuclear Science Symposium Conference Record (Cat. No.96CH35974), P1082, DOI 10.1109/NSSMIC.1996.591559
[7]   A PRACTICAL METHOD FOR INCORPORATING SCATTER IN A PROJECTOR-BACKPROJECTOR FOR ACCURATE SCATTER COMPENSATION IN SPECT [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1107-1116
[8]   MODELING THE SCATTER RESPONSE FUNCTION IN INHOMOGENEOUS SCATTERING MEDIA FOR SPECT [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1585-1593
[9]   NONITERATIVE COMPENSATION FOR THE DISTANCE-DEPENDENT DETECTOR RESPONSE AND PHOTON ATTENUATION IN SPECT IMAGING [J].
GLICK, SJ ;
PENNEY, BC ;
KING, MA ;
BYRNE, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :363-374
[10]   AN ATTENUATED PROJECTOR BACKPROJECTOR FOR ITERATIVE SPECT RECONSTRUCTION [J].
GULLBERG, GT ;
HUESMAN, RH ;
MALKO, JA ;
PELC, NJ ;
BUDINGER, TF .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (08) :799-816