How important is dosimetrist experience for intensity modulated radiation therapy? A comparative analysis of a head and neck case

被引:74
作者
Batumalai, Vikneswary [1 ,2 ]
Jameson, Michael G. [1 ,3 ]
Forstner, Dion F. [1 ,4 ]
Vial, Philip [1 ,5 ]
Holloway, Lois C. [1 ,2 ,3 ,5 ]
机构
[1] Liverpool Hosp, Canc Therapy Ctr, Sydney, NSW, Australia
[2] Univ New South Wales, Sydney, NSW, Australia
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[4] Liverpool Hosp, CCORE, Sydney, NSW, Australia
[5] Univ Sydney, Sch Med Phys, Inst Med Phys, Sydney, NSW, Australia
关键词
D O I
10.1016/j.prro.2012.06.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Treatment planning for IMRT is a complex process that requires additional training and expertise. The aim of this study was to compare and analyze IMRT plans generated by dosimetrists with varying levels of IMRT planning experience. Methods and Materials: The computed tomography (CT) data of a patient previously treated with IMRT for left tonsillar carcinoma were used. The patient's preexisting planning target volumes (PTVs) and all organs at risk were provided with the CT data set. Six dosimetrists with variable IMRT planning experience generated IMRT plans according to the department's protocol. Plan analysis included visual inspection and comparison of dose-volume histogram, conformity indices, treatment delivery efficiency, and dose delivery accuracy. Results: Visual review of the dose distribution showed that the 6 plans were comparable. However, only the 2 most experienced dosimetrists were able to meet the strict PTV aims and critical structure constraints. The least experienced dosimetrist had the worst planning outcome. Comparison of delivery efficiency showed that the number of segments, total monitor units, and treatment time increased as the IMRT planning experience decreased. Conclusions: Dosimetrists with higher levels of IMRT planning experience produced a better quality head and neck IMRT plan. Different planning experience may need to be considered when organizing appropriate departmental resources. Crown Copyright (C) 2013 Published by Elsevier Inc. on behalf of American Society for Radiation Oncology. All rights reserved.
引用
收藏
页码:E99 / E106
页数:8
相关论文
共 29 条
[11]   Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine [J].
Galvin, JM ;
Ezzell, G ;
Eisbrauch, A ;
Yu, C ;
Butler, B ;
Xiao, Y ;
Rosen, I ;
Rosenman, J ;
Sharpe, M ;
Xing, L ;
Xia, P ;
Lomax, T ;
Low, DA ;
Palta, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1616-1634
[12]   Past, present and near future of techniques in radiation oncology [J].
Gerard, J. -P. ;
Thariat, J. ;
Giraud, P. ;
Cosset, J. -M. .
BULLETIN DU CANCER, 2010, 97 (07) :743-751
[13]   Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery [J].
Ghilezan, M ;
Yan, D ;
Liang, J ;
Jaffray, D ;
Wong, J ;
Martinez, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05) :1602-1610
[14]   Radiation-induced second cancers: The impact of 3D-CRT and IMRT [J].
Hall, EJ ;
Wuu, CS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :83-88
[15]   AMERICAN SOCIETY FOR THERAPEUTIC RADIOLOGY AND ONCOLOGY (ASTRO) AND AMERICAN COLLEGE OF RADIOLOGY (ACR) PRACTICE GUIDELINES FOR INTENSITY-MODULATED RADIATION THERAPY (IMRT) [J].
Hartford, Alan C. ;
Palisca, Madeline G. ;
Eichler, Thomas T. ;
Beyer, David C. ;
Devineni, Venkata Rao ;
Ibbott, Geoffrey S. ;
Kavanagh, Brian ;
Kent, Join S. ;
Rosenthal, Seth A. ;
Schultz, Chris T. ;
Tripuraneni, Prabhakar ;
Gaspar, Laurie E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01) :9-14
[16]   Development of a dosimetry inter-comparison for IMRT as part of site credentialing for a TROG multi-centre clinical trial for prostate cancer [J].
Healy, B. ;
Frantzis, J. ;
Murry, R. ;
Martin, J. ;
Middleton, M. ;
Catton, C. ;
Kron, T. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) :195-202
[17]   INTENSITY-MODULATED RADIOTHERAPY FOR LOCALLY ADVANCED NON-SMALL-CELL LUNG CANCER: A DOSE-ESCALATION PLANNING STUDY [J].
Lievens, Yolande ;
Nulens, An ;
Gaber, Mousa Amr ;
Defraene, Gilles ;
De Wever, Walter ;
Stroobants, Sigrid ;
Van den Heuvel, Frank .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01) :306-313
[18]   Quality assurance in the 22991 EORTC ROG trial in localized prostate cancer: Dummy run and individual case review [J].
Matzinger, Oscar ;
Poortmans, Philip ;
Giraud, Jean-Yves ;
Maingon, Philippe ;
Budiharto, Tom ;
van den Bergh, Alfons C. M. ;
Davis, J. Bernard ;
Musat, Elena ;
Ataman, Fatma ;
Huyskens, Dominique P. ;
Gulyban, Akos ;
Bolla, Michel .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) :285-290
[19]   Dummy run and conformity indices in the ongoing EORTC low-grade glioma trial 22033-26033: First evaluation of quality of radiotherapy planning [J].
Musat, Elena ;
Roelofs, Erik ;
Bar-Deroma, Raquel ;
Fenton, Paul ;
Gulyban, Akos ;
Collette, Laurence ;
Stupp, Roger ;
Weber, Damien C. ;
Davis, J. Bernard ;
Aird, Edwin ;
Baumert, Brigitta G. .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :218-224
[20]   Variation in external beam treatment plan quality: An inter-institutional study of planners and planning systems [J].
Nelms, Benjamin E. ;
Robinson, Greg ;
Markham, Jay ;
Velasco, Kyle ;
Boyd, Steve ;
Narayan, Sharath ;
Wheeler, James ;
Sobczak, Mark L. .
PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) :296-305