DETERMINATION AND CONFIRMATION OF BENOMYL AND CARBENDAZIM IN WATER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND DIODE-ARRAY DETECTION

被引:6
|
作者
DHOOT, JS
DELROSARIO, AR
机构
[1] California State Department, Health Services, Sanitation and Radiation Laboratory, Berkeley, CA 94704
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 645卷 / 01期
关键词
D O I
10.1016/0021-9673(93)80632-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a direct determination of benomyl and carbendazim in a single analytical run and their confirmation by absorption spectra using diode array detection. A simple technique has been developed for preparation of benomyl calibration standard. Benomyl was dissolved in chloroform prior to a high dilution in water for HPLC. Detection limits, precision, and accuracy of data are presented. The method is simple, rapid, accurate, and precise.
引用